Pedicle axis view combined by sacral mapping can decrease fluoroscopic shot count in percutaneous iliosacral screw placement

Kadir Bahadır Alemdaroğlu, Mehmet Yücens, Talip Kara, Deniz Gül, Nevres Hürriyet Aydoğan
Injury 2014, 45 (12): 1921-7
25457343

BACKGROUND: Percutaneous iliosacral screw fixation of the posterior pelvic ring is a demanding procedure with high exposure to radiation. The conventional technique includes the use of three classical projections with the C-arm: inlet, outlet, and true lateral views. A projection in the axis of the upper sacral alar pedicles with a 30° cephalad and 30° ventral oblique view would help in obtaining a more accurate visualization of the safe corridor. Two subcutaneously placed K-wires, one placed horizontally and one vertically, may facilitate the starting point and aim changes by offering the surgeon an option for exactly matching the position of the sacrum with the image. The purpose of this study was to detect if the radiation application could be decreased by our new methodology.

METHODS: Seventeen patients with pelvic posterior ring disruptions, in which percutaneous iliosacral screw placement was indicated, were included in the study. Group 1 comprised 7 patients in whom conventional projections and technique were used. Group 2 comprised 10 patients in whom 30°–30° projection and sacral mapping technique via two subcutaneous K-wires were applied. Radiation exposure time, total fluoroscopic shot count, fluoroscopic shot count needed for only guide wire and screw placement, radiation dose, and complications were compared between the two groups.

RESULTS: The median number of fluoroscopic images for guide and screw placement was 132 (56–220) and 29.5 (19–83) in Groups 1 and 2, respectively, and the difference was statistically significant (p < 0.001). The median total fluoroscopic radiation time was 138 (68–234) and 52 (28–77) s in Groups 1 and 2, respectively, and the difference was significant (p < 0.001). Group 1 had a significantly higher median radiation dose than Group 2 [3020 (1502–6032) vs. 1192 (426–2359); (p = 0.001)].

CONCLUSIONS: Iliosacral screw placement with the help of sacral mapping and a fourth view, “30°–30°”, helps the surgeon to markedly reduce the fluoroscopic shots, radiation time and dose during guide wire and screw placement.

LEVEL OF EVIDENCE: Therapeutic, Level II.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
25457343
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"