COMPARATIVE STUDY
JOURNAL ARTICLE

3.0T, time-resolved, 3D flow-sensitive MR in the thoracic aorta: Impact of k-t BLAST acceleration using 8- versus 32-channel coil arrays

Arshad Zaman, Manish Motwani, James J Oliver, Gerard Crelier, Laura E Dobson, David M Higgins, Sven Plein, John P Greenwood
Journal of Magnetic Resonance Imaging: JMRI 2015, 42 (2): 495-504
25447784

PURPOSE: To evaluate the performance of 4D flow MR in the thoracic aorta with 8- and 32-channel coil arrays using k-t BLAST and SENSE acceleration techniques and compare this to a conventional 2D SENSE approach.

MATERIALS AND METHODS: Fifteen healthy subjects and eight patients underwent magnetic resonance imaging (MRI) at 3.0T using: 1) 2D SENSE phase contrast velocity mapping as the reference standard and 2) 4D-flow pulse sequences accelerated with SENSE and k-t BLAST, using both 8- and 32-channel coil arrays. Data processing was performed using GT Flow. Image quality of the magnitude images and pathline visualization were graded and mean scan times, flow, peak velocity, stroke volume, and image quality were compared between techniques.

RESULTS: Mean scan times were significantly lower for 4D-flow sequences accelerated with k-t BLAST compared to SENSE (5.5 vs. 25.2 min; P < 0.01). 4D k-t BLAST acquisition had greater magnitude and pathline image quality than 4D SENSE acquisition for both 32-channel and 8-channel data (P < 0.001); both 4D SENSE and 4D k-t BLAST acquisitions had significantly greater image quality when 32 channels were utilized compared to 8 (P < 0.05). On Bland-Altman analysis, all 4D flow pulse sequences showed significant agreement with the 2D SENSE reference for peak velocity measurement (P > 0.05); the lowest bias being observed with the 4D 32 channel k-t BLAST sequence. There were no significant differences in measured flow, peak velocity, or stroke volume with any of the four investigated 4D acquisition techniques compared to reference technique values (P > 0.05). In patients, there were no significant differences in flow, peak velocity, or stroke volume measurements between 32-channel 4D k-t BLAST and the reference acquisition.

CONCLUSION: 4D flow MR using k-t BLAST and 32 channel coils allows a reduction in total scan time while improving overall image quality compared to a standard 2D SENSE and 4D SENSE acquisitions. The use of 32 channels rather than 8 channels with the 4D k-t BLAST was also preferable in terms of image quality.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
25447784
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"