JOURNAL ARTICLE
MULTICENTER STUDY
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Left ventricular ejection fraction normalization in cardiac resynchronization therapy and risk of ventricular arrhythmias and clinical outcomes: results from the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) trial.

Circulation 2014 December 24
BACKGROUND: Appropriate guideline criteria for use of implantable cardioverter-defibrillators (ICDs) do not take into account potential recovery of left ventricular ejection fraction (LVEF) in patients treated with CRT-defibrillator.

METHODS AND RESULTS: Patients randomized to CRT-defibrillator from the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) trial who survived and had paired echocardiograms at enrollment and at 12 months (n=752) were included. Patients were evaluated by LVEF recovery in 3 groups (LVEF ≤35% [reference], 36%-50%, and >50%) on outcomes of ventricular tachyarrhythmias (VTAs), VTA ≥200 bpm, ICD shock, heart failure or death, and inappropriate ICD therapy by multivariable Cox models. A total of 7.3% achieved LVEF normalization (>50%). The average follow-up was 2.2±0.8 years. The risk of VTA was reduced in patients with LVEF >50% (hazard ratio [HR], 0.24; 95% confidence interval [CI], 0.07-0.82; P=0.023) and LVEF of 36% to 50% (HR, 0.44; 95% CI, 0.28-0.68; P<0.001). Among patients with LVEF >50%, only 1 patient had VTA ≥200 bpm (HR, 0.16; 95% CI, 0.02-1.51), none were shocked by the ICD, and 2 died of nonarrhythmic causes. The risk of HF or death was reduced with improvements in LVEF (LVEF >50%: HR, 0.29; 95% CI, 0.09-0.97; P=0.045; and LVEF of 36%-50%: HR, 0.44; 95% CI, 0.28-0.69; P<0.001). For inappropriate ICD therapy, no additional risk reduction for LVEF>50% was seen compared with an LVEF of 36% to 50%. A total of 6 factors were associated with LVEF normalization, and patients with all factors present (n=42) did not experience VTAs (positive predictive value, 100%).

CONCLUSIONS: Patients who achieve LVEF normalization (>50%) have very low absolute and relative risk of VTAs and a favorable clinical course within 2.2 years of follow-up. Risk of inappropriate ICD therapy is still present, and these patients could be considered for downgrade from CRT-defibrillator to CRT-pacemaker at the time of battery depletion if no VTAs have occurred.

CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT00180271.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app