Randomized Trial Comparing the Flexible 19G and 25G Needles for Endoscopic Ultrasound-Guided Fine Needle Aspiration of Solid Pancreatic Mass Lesions.
Pancreas 2015 January
OBJECTIVES: Although a large gauge needle can procure more tissue at endoscopic ultrasound-guided fine needle aspiration (EUS-FNA), its advantage over smaller needles is unclear. This study compared flexible 19G and 25G needles for EUS-FNA of solid pancreatic masses.
METHODS: This was a randomized trial of patients undergoing EUS-FNA of pancreatic masses using flexible 19G or 25G needle. Main outcome measure was to compare median number of passes for on-site diagnosis. Secondary measures were to compare specimen bloodiness, complications, technical failures, and histological core tissue procurement.
RESULTS: One hundred patients were randomized to EUS-FNA using flexible 19G or 25G needle. Median of 1 pass was required to achieve on-site diagnosis of 96% and 92% (P = 0.68) in 19G and 25G cohorts. There was no significant difference in technical failure (0% vs 2%, P = 0.99) or adverse events (2% vs 0%, P = 0.99) between 19G and 25G cohorts. Although histological core tissue procurement was significantly better with flexible 19G needle (88% vs 44%, P < 0.001), specimens were bloodier (severe bloodiness, 36% vs 4%; P < 0.001).
CONCLUSIONS: As there is no significant difference in the performance of flexible 19G and 25G needles, needle choice for sampling pancreatic masses should be based on endoscopist preference and need for histology.
METHODS: This was a randomized trial of patients undergoing EUS-FNA of pancreatic masses using flexible 19G or 25G needle. Main outcome measure was to compare median number of passes for on-site diagnosis. Secondary measures were to compare specimen bloodiness, complications, technical failures, and histological core tissue procurement.
RESULTS: One hundred patients were randomized to EUS-FNA using flexible 19G or 25G needle. Median of 1 pass was required to achieve on-site diagnosis of 96% and 92% (P = 0.68) in 19G and 25G cohorts. There was no significant difference in technical failure (0% vs 2%, P = 0.99) or adverse events (2% vs 0%, P = 0.99) between 19G and 25G cohorts. Although histological core tissue procurement was significantly better with flexible 19G needle (88% vs 44%, P < 0.001), specimens were bloodier (severe bloodiness, 36% vs 4%; P < 0.001).
CONCLUSIONS: As there is no significant difference in the performance of flexible 19G and 25G needles, needle choice for sampling pancreatic masses should be based on endoscopist preference and need for histology.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app