Journal of Orthopaedics and Traumatology : Official Journal of the Italian Society of Orthopaedics and Traumatology 2014 December
BACKGROUND: The objective of the study was to compare the efficacy of external fixation and volar plating on the functional parameter of displaced intra-articular (Cooney's type IV) distal end radius fractures using the Green and O'Brien scoring system.
MATERIALS AND METHODS: This prospective randomized study comprised 68 patients treated with external fixation and 42 patients treated with volar locking plates. The patients were followed up at 6 months and 1 year after surgery. The assessment of pain, range of motion, grip strength and activity were assessed at each follow-up visit and scored according to the Green and O'Brien scoring system.
RESULTS: At 1 year after surgery, we observed that external fixation showed significantly better results than volar locking plates using the Green and O'Brien scores for range of motion (22.0 ± 4.77 vs 19.89 ± 5.05), grip strength (19.91 ± 5.4 vs 16.89 ± 4.4) and final outcome (87.36 ± 11.62 vs 81.55 ± 11.32). No difference was found in pain and activity between these two groups of patients. Patients aged <50 years treated with external fixation showed excellent results (final score (91.57 ± 9.01) at 1 year follow-up.
CONCLUSION: External fixation showed superiority over volar locked plating after 1 year of surgery.
LEVEL OF EVIDENCE: IV.
MATERIALS AND METHODS: This prospective randomized study comprised 68 patients treated with external fixation and 42 patients treated with volar locking plates. The patients were followed up at 6 months and 1 year after surgery. The assessment of pain, range of motion, grip strength and activity were assessed at each follow-up visit and scored according to the Green and O'Brien scoring system.
RESULTS: At 1 year after surgery, we observed that external fixation showed significantly better results than volar locking plates using the Green and O'Brien scores for range of motion (22.0 ± 4.77 vs 19.89 ± 5.05), grip strength (19.91 ± 5.4 vs 16.89 ± 4.4) and final outcome (87.36 ± 11.62 vs 81.55 ± 11.32). No difference was found in pain and activity between these two groups of patients. Patients aged <50 years treated with external fixation showed excellent results (final score (91.57 ± 9.01) at 1 year follow-up.
CONCLUSION: External fixation showed superiority over volar locked plating after 1 year of surgery.
LEVEL OF EVIDENCE: IV.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app