Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Standard endovascular treatment of abdominal aortic aneurysms in patients with very short proximal necks using the Endurant stent graft.

OBJECTIVE: This study evaluated and compared the midterm results of endovascular aortic aneurysm repair with the Endurant (Medtronic Inc, Santa Rosa, Calif) stent graft system in off-label use in patients with short (<10 mm) proximal aortic necks and in patients treated according to device-specific instructions for use.

METHODS: This was a case-control (2:1) single-center retrospective analysis of prospectively collected data performed between September 2008 and December 2012. Analysis identified 19 elective patients with short (<10 mm) proximal necks and mild angulations (≤45°) treated with the Endurant stent graft and 38 patients matched for age, sex, and aneurysm diameter with proximal aortic necks ≥10 mm in length who met the instructions for use. End points included technical and clinical success and freedom from any secondary intervention, any type of endoleak, and aneurysm-related death.

RESULTS: The short-neck group was a mean ± standard deviation age of 71.7 ± 8.9 years, 84% were men, and their mean infrarenal aortic neck length was 6.1 ± 1.2 mm. Mean suprarenal and infrarenal angles were 110° ± 10.4° and 170° ± 15.4°, respectively. Aortic neck diameters were similar between the groups (26.6 ± 3.8 vs 25.7 ± 3.7 mm; P = .36). Primary technical success was achieved in all cases. Off-label patients were more likely to require additional proximal cuff deployment to successfully obtain a seal (21% vs 3%; P = .04). The two patient groups were similar in rates of perioperative mortality, morbidity, and complications. Mean follow-up of 24 ± 12 months revealed no differences in clinical success, freedom from reintervention, and aneurysm-related death. No type I endoleaks were observed in either group during the follow-up period.

CONCLUSIONS: The Endurant stent graft system applied off-label in patients with very short aneurysm necks (<10 mm) with mild angulation showed acceptable treatment results. These midterm results might suggest its use in carefully selected patients with very short neck anatomy. Long-term data are needed to verify the observed durability of the Endurant stent graft.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app