ABSORB biodegradable stents versus second-generation metal stents: a comparison study of 100 complex lesions treated under OCT guidance.

OBJECTIVES: The aim of this study was to compare the acute performance of the PLLA ABSORB bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) with second-generation metal drug-eluting stents (DES) in complex coronary artery lesions.

BACKGROUND: Thick polymer-based BVS have different mechanical properties than thin second-generation DES. Data on the acute performance of BVS are limited to simple coronary lesions treated in trials with strict inclusion criteria.

METHODS: Fifty complex coronary lesions (all type American College of Cardiology/American Heart Association B2-C) treated with a BVS undergoing a final optical coherence tomography (OCT) examination were compared with an equal number of matched lesions treated with second-generation DES. The following stent performance indexes were assessed with OCT: mean and minimal area, residual area stenosis (RAS), incomplete strut apposition (ISA), tissue prolapse, eccentricity index, symmetry index, strut fracture, and edge dissection.

RESULTS: One hundred lesions from 73 patients were analyzed. A higher balloon diameter/reference vessel diameter ratio was used for predilation in the BVS group (p < 0.01). Most of the BVS and DES were post-dilated with short noncompliant (NC) balloons of similar diameter. OCT showed in the BVS group a higher tissue prolapse area (p = 0.08) and greater incidence of ISA at the proximal edge (p = 0.04) with no difference in the overall ISA. The RAS was 20.2% in the BVS group and 21.7% in the DES group (p = 0.32). There was no difference in the eccentricity index. The minimal and mean lumen areas were similar in the 2 groups. Two cases of strut fractures occurred after the BVS, whereas none was observed in the DES.

CONCLUSIONS: Based on OCT, the BVS showed similar post-procedure area stenosis, minimal lumen area, and eccentricity index as second-generation DES. The different approach for lesion preparation and routine use of OCT guidance during BVS expansion may have contributed to these results.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app