Arm Volumetry Versus Upper Extremity Lymphedema Index: Validity of Upper Extremity Lymphedema Index for Body-Type Corrected Arm Volume Evaluation.
Annals of Plastic Surgery 2016 June
BACKGROUND: Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume.
METHODS: Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, <20 kg/m), middle BMI (BMI, 20-25 kg/m), and high BMI (BMI, >25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups.
RESULTS: Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P < 0.001]. There was no significant difference in UEL index between BMI groups [low BMI vs middle BMI vs high BMI, 97.2 (4.2) vs 96.6 (4.6) vs 96.7 (9.9), P > 0.5].
CONCLUSIONS: Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.
METHODS: Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, <20 kg/m), middle BMI (BMI, 20-25 kg/m), and high BMI (BMI, >25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups.
RESULTS: Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P < 0.001]. There was no significant difference in UEL index between BMI groups [low BMI vs middle BMI vs high BMI, 97.2 (4.2) vs 96.6 (4.6) vs 96.7 (9.9), P > 0.5].
CONCLUSIONS: Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app