We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Comparison of ABO antibody titers on the basis of the antibody detection method used.
Annals of Laboratory Medicine 2014 July
BACKGROUND: Detection methods for ABO antibody (Ab) titers vary across laboratories, and the results are different depending on the method used. We aimed to compare titer values using different detection methods for the measurement of ABO Ab titers.
METHODS: For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without dithiothreitol treatment. The room-temperature (RT) incubation technique and the indirect antiglobulin test (IAT) were used in the tube test and gel card test. Flow cytometry (FCM) was performed by using anti-IgM and anti-IgG Abs.
RESULTS: Regardless of the blood groups tested, the FCM assay with anti-IgM showed the highest titer compared to the tube test and gel card test with RT incubation in both. The tube test with IAT showed a higher titer than the gel card test with IAT (Gel-IAT) or FCM with anti-IgG in blood group A and B, while Gel-IAT showed the highest titer relative to the other tests, only for the anti-A Ab in blood group O.
CONCLUSIONS: There were significant differences in the titers depending on the detection method used, and each method showed a different detection capacity for each ABO Ab depending on the ABO blood group tested. Therefore, caution should be exercised in interpreting ABO Ab titer results, taking into consideration the detection method used and the blood group.
METHODS: For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without dithiothreitol treatment. The room-temperature (RT) incubation technique and the indirect antiglobulin test (IAT) were used in the tube test and gel card test. Flow cytometry (FCM) was performed by using anti-IgM and anti-IgG Abs.
RESULTS: Regardless of the blood groups tested, the FCM assay with anti-IgM showed the highest titer compared to the tube test and gel card test with RT incubation in both. The tube test with IAT showed a higher titer than the gel card test with IAT (Gel-IAT) or FCM with anti-IgG in blood group A and B, while Gel-IAT showed the highest titer relative to the other tests, only for the anti-A Ab in blood group O.
CONCLUSIONS: There were significant differences in the titers depending on the detection method used, and each method showed a different detection capacity for each ABO Ab depending on the ABO blood group tested. Therefore, caution should be exercised in interpreting ABO Ab titer results, taking into consideration the detection method used and the blood group.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app