JOURNAL ARTICLE

Optical coherence tomography-guided bifurcation stenting of a coronary artery dissection

Nienke S van Ditzhuijzen, Jurgen Ligthart, Shengxian Tu, Marc van der Linden, Evelyn Regar
Canadian Journal of Cardiology 2014, 30 (8): 956.e11-4
24975190
Periprocedural guide wire-induced coronary artery dissection is a rare but potentially serious complication of percutaneous coronary intervention. Immediate stenting of the entry point is one of the therapeutic options but engaging the guide wire in the true lumen might be challenging. We report a case of a 55-year-old woman with a guide wire-induced coronary dissection that occurred during treatment of a bifurcation lesion. Optical coherence tomography was instrumental in distinguishing true from false lumen and thereby guide correct positioning of the guide wire to successfully treat the lesion using a dedicated bifurcation stent.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
24975190
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"