To Evaluate the Accuracy of Saline Infusion Sonohysterography (SIS) for Evaluation of Uterine Cavity Abnormalities in Patients with Abnormal Uterine Bleeding.
OBJECTIVE: To evaluate the accuracy of transvaginal sonography (TVS) and saline infusion sonohysterography (SIS) for detection of uterine cavity abnormalities in patients with abnormal uterine bleeding (AUB) taking hysteroscopy as the gold standard.
METHODS: This was a prospective study done in the department of Obstetrics and Gynecology of a tertiary care academic hospital. Sixty premenopausal and postmenopausal women who presented with AUB underwent TVS, SIS, and hysteroscopy. The presence of focal abnormality and the type of abnormality, i.e., polyp, submucous myoma, and endometrial hyperplasia, were noted. The results of TVS and SIS were compared with hysteroscopy.
RESULTS: On hysteroscopy, 76.67 % (n = 46) patients were diagnosed with intra cavity abnormalities. SIS showed sensitivity, specificity, PPV, and NPV of 89.1, 100, 100, and 73.7 %, respectively. In comparison, TVS showed sensitivity, specificity, PPV, and NPV of 43.48, 78.57, 86.96, and 29.73 %, respectively.
CONCLUSIONS: SIS was found to be more sensitive and specific than TVS in detection of intra cavity abnormalities.
METHODS: This was a prospective study done in the department of Obstetrics and Gynecology of a tertiary care academic hospital. Sixty premenopausal and postmenopausal women who presented with AUB underwent TVS, SIS, and hysteroscopy. The presence of focal abnormality and the type of abnormality, i.e., polyp, submucous myoma, and endometrial hyperplasia, were noted. The results of TVS and SIS were compared with hysteroscopy.
RESULTS: On hysteroscopy, 76.67 % (n = 46) patients were diagnosed with intra cavity abnormalities. SIS showed sensitivity, specificity, PPV, and NPV of 89.1, 100, 100, and 73.7 %, respectively. In comparison, TVS showed sensitivity, specificity, PPV, and NPV of 43.48, 78.57, 86.96, and 29.73 %, respectively.
CONCLUSIONS: SIS was found to be more sensitive and specific than TVS in detection of intra cavity abnormalities.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app