JOURNAL ARTICLE

Breathing adapted radiation therapy in comparison with prone position to reduce the doses to the heart, left anterior descending coronary artery, and contralateral breast in whole breast radiation therapy

Karolien Verhoeven, Caroline Sweldens, Saskia Petillion, Annouschka Laenen, Stéphanie Peeters, Hilde Janssen, Erik Van Limbergen, Caroline Weltens
Practical Radiation Oncology 2014, 4 (2): 123-129
24890353

PURPOSE: To compare 3 different treatment positions in whole breast radiation therapy in terms of target volume coverage and doses to the organs at risk (OAR).

METHODS AND MATERIALS: Thirty-four breast cancer (BC) patients (17 right-sided and 17 left-sided) were included in this dosimetric planning study. They all underwent a computed tomography (CT) scan in standard supine position in free-breathing (FB), supine position with gating in deep inspiratory breath hold (DIBH)(G), and prone position (P). Three-dimensional treatment plans were made for all 3 CTs. Target coverage and OAR sparing were evaluated.

RESULTS: Breast volumes varied between 209 and 2814 cm(3). The target coverage, expressed as the mean volume of the breast receiving at least 95% of the prescription dose, was similar for the 3 treatment positions. The mean lung dose and the volume of the lungs receiving >20 Gy were significantly lower in P (1.7 Gy; 2.3%) compared with G (3.4 Gy; 5.6%; P < .0001) and FB (4 Gy; 7.3%; P < .0001). The volume of the contralateral breast receiving >5 Gy was significantly lower in G (P = .001) or FB (P = .004) versus prone. The supine position with gating in DIBH significantly reduced the volume of the heart receiving >30 Gy (V30(heart)), the mean heart (D(heart)), and mean left anterior descending coronary artery (LAD) dose (D(LAD)) for left-sided BC patients (V30(heart) 0.9%, D(heart) 1.6 Gy, DLAD 22.4 Gy) with respect to FB (V30(heart) 4.3%, D(heart) 3.5 Gy, DLAD 30.9 Gy)(V30(heart) and mean D(heart): P ≤ .0001; mean D(LAD): P = .008) and P (V30(heart) 7.9%, D(heart) 5.4 Gy, D(LAD) 36.4 Gy)(V30(heart) and mean D(heart): P = .0004; mean D(LAD): P = .01).

CONCLUSIONS: The coverage of the planning target volume breast was equal for the 3 treatment positions. The lowest doses to the lungs were achieved in prone. The heart, LAD, and contralateral breast were best spared in the supine position with gating in DIBH.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
24890353
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"