[Long-term follow-up of the femoral artery after total percutaneous endovascular aortic repair with preclose technique using a vascular closure device].

OBJECTIVE: To evaluate the long-term outcome of the femoral artery following total percutaneous endovascular aortic repair (EVAR) with preclose technique using a vascular closure device (VCD).

METHODS: From July, 2009 to July, 2012, total percutaneous EVAR was performed in 113 patients (106 males, 7 females; mean age 59.4∓13.5 years) with pre-close technique, including 60 with Stanford type B aortic dissection, 3 with thoracic aortic aneurysm, and 48 with infra-renal abdominal aortic aneurysm, and 2 with thoracic and abdominal aortic aneurysms. The Technical success and complication rates were evaluated, and the outcomes of the femoral artery were followed up with computed tomography or color Doppler ultrasound.

RESULTS: The overall technical success rate was 97.6% (161/165) with conversion to open surgery in 4 cases. The size of the sheaths used were 24Fr (n=37), 22Fr (n=29), 20Fr (n=24), 18Fr (n=25), 16Fr (n=12) and 14 Fr (n=38), and 347 VCDs were used for hemostasis of 165 femoral sites; 147 femoral sites were closed using 2 VCDs. Four access-related adverse events, including femoral arterial-venous fistula, acute femoral thrombosis, bleeding, and lower extremity ischemia, occurred in 4 (2.4%) of the 165 cases. In cases using ≤18Fr sheaths, the success rate of closure using 2 VCDs was 98.7%, as compared to 81.1% in cases using larger (≥20Fr) sheaths (P=0.0003). The success rate of the 82 anterior sites was lower than that of the 82 posterior sites (82.9% vs 95.2%, P=0.013). No lower extremity ischemia was observed, nor was femoral artery stenosis detected during the follow-up for 26∓9 months (12-50 months) in these cases.

CONCLUSION: Total percutaneous EVAR with preclose technique using VCD provides a safe and effective alternative to open femoral surgery. The sheath size can be a predictor of percutaneous access failure to require conversion to open femoral surgery or using more than 2 devices for suture. Total percutaneous endovascular aortic repair using VCD with preclose technique is safe and effective, which can be adopted as an alternative technique of surgically femoral arterial cut-down operation when the surgeon reduce the learning curve.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app