Add like
Add dislike
Add to saved papers

Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study.

Radiology 2014 September
PURPOSE: To investigate whether dual-energy multi-detector row computed tomography (CT) with virtual monochromatic imaging can overcome renal cyst pseudoenhancement in a phantom experiment and a clinical study.

MATERIALS AND METHODS: This retrospective single-center HIPAA-compliant study was approved by the institutional review board, with waiver of informed consent. Four renal compartments inserted into torso phantoms were filled with saline to simulate the unenhanced state and with iodinated solutions to simulate the three levels of renal parenchyma enhancement (140, 180, and 240 HU). Saline-filled spheres simulating renal cysts (15 and 18 mm in diameter) were serially suspended in the renal compartments and imaged with dual-energy and single-energy multi-detector row CT at four different energy levels (80, 100, 120, and 140 kVp). In addition, 28 patients (mean age, 66 years ± 10; mean body mass index, 31.3 kg/m(2) ± 6.2) with 34 intrarenal cysts were included. Virtual monochromatic images were reconstructed in 10-keV increments at energy levels ranging from 40 to 140 keV. Phantom and clinical data were analyzed by using multivariate regression analysis.

RESULTS: In the phantom experiment, all polychromatic image data sets showed pseudoenhancement (postcontrast attenuation increase >10 HU) in all investigated conditions, with a significant effect on cyst size (P <.001), location (P <.001), and renal background attenuation level (P <.001). Virtual monochromatic images at energy levels ranging from 80 to 140 keV did not show pseudoenhancement, with the minimum attenuation increase (mean, 6.1 HU ± 1.6; range, 1.6-7.7 HU) on 80-keV images. In patients, pseudoenhancement never occurred on virtual monochromatic images at energy levels ranging from 90 to 140 keV. Patient body size had a significant effect (P = .007) on selection of the optimal monochromatic energy level.

CONCLUSION: Dual-energy multi-detector row CT with reconstruction of virtual monochromatic images at an optimal energy level can overcome renal cyst pseudoenhancement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app