JOURNAL ARTICLE

Intra-aortic balloon pump effects on macrocirculation and microcirculation in cardiogenic shock patients supported by venoarterial extracorporeal membrane oxygenation*

Thibaut Petroni, Anatole Harrois, Julien Amour, Guillaume Lebreton, Nicolas Brechot, Sébastien Tanaka, Charles-Edouard Luyt, Jean-Louis Trouillet, Jean Chastre, Pascal Leprince, Jacques Duranteau, Alain Combes
Critical Care Medicine 2014, 42 (9): 2075-82
24810530

OBJECTIVES: This study was designed to assess the effects on macrocirculation and microcirculation of adding an intra-aortic balloon pump to peripheral venoarterial extracorporeal membrane oxygenation in patients with severe cardiogenic shock and little/no residual left ventricular ejection.

DESIGN: A prospective, single-center, observational study where macrocirculation and microcirculation were assessed with clinical-, Doppler echocardiography-, and pulmonary artery-derived hemodynamic variables and also cerebral and thenar eminence tissue oxygenation and side-stream dark-field imaging of sublingual microcirculation.

SETTING: A 26-bed tertiary ICU in a university hospital.

PATIENTS: We evaluated 12 consecutive patients before and 30 minutes after interrupting and restarting intra-aortic balloon pump.

INTERVENTIONS: Measurements were performed before, and 30 minutes after interrupting and restarting intra-aortic balloon pump.

MEASUREMENTS AND MAIN RESULTS: Stopping intra-aortic balloon pump was associated with higher pulmonary artery-occlusion pressure (19 ± 10 vs 15 ± 8 mm Hg, p = 0.01), increased left ventricular end-systolic (51 ± 13 vs 50 ± 14 mm, p = 0.05) and end-diastolic (55 ± 13 vs 52 ± 14 mm, p = 0.003) dimensions, and decreased pulse pressure (15 ± 13 vs 29 ± 22 mm Hg, p = 0.02). Maximum pulmonary artery-occlusion pressure reduction when the intra-aortic balloon pump was restarted was observed in the seven patients whose pulmonary artery-occlusion pressure was more than 15 mm Hg when intra-aortic balloon pump was off (-6.6 ± 4.3 vs -0.6 ± 3.4 mm Hg, respectively). Thenar eminence and brain tissue oxygenation and side-stream dark-field-assessed sublingual microcirculation were unchanged by stopping and restarting intra-aortic balloon pump.

CONCLUSIONS: Restoring pulsatility and decreasing left ventricular afterload with intra-aortic balloon pump was associated with smaller left ventricular dimensions and lower pulmonary artery pressures but did not affect microcirculation variables in cardiogenic shock patients with little/no residual left ventricular ejection while on peripheral venoarterial extracorporeal membrane oxygenation.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
24810530
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"