OBJECTIVES: This study was designed to assess the effects on macrocirculation and microcirculation of adding an intra-aortic balloon pump to peripheral venoarterial extracorporeal membrane oxygenation in patients with severe cardiogenic shock and little/no residual left ventricular ejection.

DESIGN: A prospective, single-center, observational study where macrocirculation and microcirculation were assessed with clinical-, Doppler echocardiography-, and pulmonary artery-derived hemodynamic variables and also cerebral and thenar eminence tissue oxygenation and side-stream dark-field imaging of sublingual microcirculation.

SETTING: A 26-bed tertiary ICU in a university hospital.

PATIENTS: We evaluated 12 consecutive patients before and 30 minutes after interrupting and restarting intra-aortic balloon pump.

INTERVENTIONS: Measurements were performed before, and 30 minutes after interrupting and restarting intra-aortic balloon pump.

MEASUREMENTS AND MAIN RESULTS: Stopping intra-aortic balloon pump was associated with higher pulmonary artery-occlusion pressure (19 ± 10 vs 15 ± 8 mm Hg, p = 0.01), increased left ventricular end-systolic (51 ± 13 vs 50 ± 14 mm, p = 0.05) and end-diastolic (55 ± 13 vs 52 ± 14 mm, p = 0.003) dimensions, and decreased pulse pressure (15 ± 13 vs 29 ± 22 mm Hg, p = 0.02). Maximum pulmonary artery-occlusion pressure reduction when the intra-aortic balloon pump was restarted was observed in the seven patients whose pulmonary artery-occlusion pressure was more than 15 mm Hg when intra-aortic balloon pump was off (-6.6 ± 4.3 vs -0.6 ± 3.4 mm Hg, respectively). Thenar eminence and brain tissue oxygenation and side-stream dark-field-assessed sublingual microcirculation were unchanged by stopping and restarting intra-aortic balloon pump.

CONCLUSIONS: Restoring pulsatility and decreasing left ventricular afterload with intra-aortic balloon pump was associated with smaller left ventricular dimensions and lower pulmonary artery pressures but did not affect microcirculation variables in cardiogenic shock patients with little/no residual left ventricular ejection while on peripheral venoarterial extracorporeal membrane oxygenation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app