Predictive properties of the video head impulse test: measures of caloric symmetry and self-report dizziness handicap.

Ear and Hearing 2014 September
OBJECTIVES: The purpose of this investigation was to determine whether a predictable relationship existed between self-reported dizziness handicap and video Head Impulse Test (vHIT) results in a large sample of patients reporting to a dizziness clinic. Secondary objectives included describing the characteristics of the vHIT ipsilesional and contralesional vestibulo-ocular reflex slow-phase velocity in patients with varying levels of canal paresis. Finally, the authors calculated the sensitivity and specificity of the vHIT for detecting horizontal semicircular canal impairment using the caloric test as the "gold standard."

DESIGN: Participants were 115 adults presenting to a tertiary medical care center with symptoms of dizziness. Participants were administered a measure of self-report dizziness handicap (i.e., Dizziness Handicap Inventory) and underwent caloric testing and vHIT at the same appointment.

RESULTS: Results showed that (1) there were no significant group differences (i.e., vHIT normal versus vHIT abnormal) in the Dizziness Handicap Inventory total score, (2) both ipsilesional and contralateral velocity gain decreased with increases in caloric paresis, and (3) a caloric asymmetry of 39.5% was determined to be the cutoff that maximized discrimination of vHIT outcome.

CONCLUSIONS: The level of self-reported dizziness handicap is not predicted by the outcome of the vHIT, which is consistent with the majority of published reports describing the poor relationship between quantitative tests of vestibular function and dizziness handicap. Further, the study findings have demonstrated that vHIT and caloric data are not redundant, and each test provides unique information regarding the functional integrity of the horizontal semicircular canal at different points on the frequency spectrum. The vHIT does offer some advantages over caloric testing, but at the expense of sensitivity. The vHIT can be completed in less time, is not noxious to the patient, and requires very little laboratory space. However, the study data show that a caloric asymmetry of 39.5% is required to optimize discrimination between an abnormal and normal vHIT. It is the authors' contention that the vHIT is a complementary test to the balance function examination and should viewed as such rather than as a replacement for caloric testing.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app