PURPOSE: The objective of this study was to investigate cancellous bone response to strontium-doped hydroxyapatite (SrHA) in ovariectomized (OVX) rats.
METHODS: Hydroxyapatite (HA) and 10%SrHA (HA with 10 mol% calcium substituted by strontium) implants were prepared and characterized by scanning electronic microscopy (SEM), energy dispersive microanalysis (EDX) and X-ray diffraction (XRD). Twelve weeks after bilateral ovariectomy, 20 rats randomly received HA or 10%SrHA implants in the right distal femur, with 10 animals in each group. Eight weeks after implantation, specimens were harvested and analyzed by micro-computed tomography (micro-CT) and histology.
RESULTS: Compared with HA, 10%SrHA raised the percentage bone volume by 42.6%, bone-to-implant contact by 47.1%, mean trabecular number by 27.3%, mean trabecular thickness by 31.5% and mean connectivity density by 37.4%, while it decreased mean trabecular separation by 20.1% in micro-CT evaluation. 10%SrHA also increased the bone area density by 47.6% in histological analysis.
CONCLUSIONS: With the HA implants as controls, the 10%SrHA implants were shown to increase bone density and bone-to-implant contact, and improve trabecular architecture in the vicinity of implant surfaces.
METHODS: Hydroxyapatite (HA) and 10%SrHA (HA with 10 mol% calcium substituted by strontium) implants were prepared and characterized by scanning electronic microscopy (SEM), energy dispersive microanalysis (EDX) and X-ray diffraction (XRD). Twelve weeks after bilateral ovariectomy, 20 rats randomly received HA or 10%SrHA implants in the right distal femur, with 10 animals in each group. Eight weeks after implantation, specimens were harvested and analyzed by micro-computed tomography (micro-CT) and histology.
RESULTS: Compared with HA, 10%SrHA raised the percentage bone volume by 42.6%, bone-to-implant contact by 47.1%, mean trabecular number by 27.3%, mean trabecular thickness by 31.5% and mean connectivity density by 37.4%, while it decreased mean trabecular separation by 20.1% in micro-CT evaluation. 10%SrHA also increased the bone area density by 47.6% in histological analysis.
CONCLUSIONS: With the HA implants as controls, the 10%SrHA implants were shown to increase bone density and bone-to-implant contact, and improve trabecular architecture in the vicinity of implant surfaces.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app