JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media.

INTRODUCTION: Following the trend of low-radiation dose computed tomographic (CT) imaging, concerns regarding the detectability of low-contrast lesions have been growing. The goal of this research was to evaluate whether a new image-based algorithm (Mono+) for virtual monoenergetic imaging with a dual-energy CT scanner can improve the contrast-to-noise ratio (CNR) and conspicuity of these low-contrast objects when using iodinated contrast media.

MATERIALS AND METHODS: Four circular phantoms of different diameter (10-40 cm) with an iodine insert at the center were scanned at a fixed radiation dose with different single- (80, 100, 120 kV) and dual-energy protocols (80/140 kV, 80/140 Sn kV, 100/140 Sn kV) using a dual-source CT system. In addition, an anthropomorphic abdominal phantom with different low-contrast lesions was scanned with the settings previously mentioned but also at only a half and a quarter of the initial dose. Dual-energy data were processed, and virtual monoenergetic images (range, 40-190 keV) were generated. Beside the established technique, a newly developed prototype algorithm to calculate monoenergetic images (Mono+) was used. To avoid noise increase at lower calculated energies, which is a known drawback of virtual monoenergetic images at low kilo electron-volt, a regional spatial frequency-based recombination of the high signal at lower energies and the superior noise properties at medium energies is performed to optimize CNR in case of Mono+ images. The CNR and low-contrast detectability were evaluated.

RESULTS: For all phantom sizes, the Mono+ technique provided increasing iodine CNR with decreasing kilo electron-volt, with the optimum CNR obtained at the lowest energy level of 40 keV. For all investigated phantom sizes, CNR of Mono+ images at low kilo electron-volt was superior to the CNR in single-energy images at an equivalent radiation dose and even higher than the CNR obtained with 80-kV protocols. In case of the anthropomorphic phantom, low-contrast detectability in monoenergetic images was, for all settings, similar to the circular phantoms, best for the voltage combination 80/140 Sn kV, irrespective of the dose level. For all dual-energy voltage combinations, the Mono+ algorithm led to superior results compared with single-energy imaging.

DISCUSSION: With regard to optimized iodine CNR, it is more efficient to perform dual-energy scans and compute virtual monoenergetic images at 40 keV using the Mono+ technique than to perform low kilovolt scans. Given the improved CNR, the Mono+ algorithm could be very useful in improving both detection and differential diagnosis of abdominal lesions, specifically low-contrast lesions, as well as in other anatomical regions where improved iodine CNR is beneficial.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app