The University of Oklahoma-College of Pharmacy has installed the first Biomarker Generator (BG75) comprising a self-shielded 7.5-MeV proton beam positive ion cyclotron and an aseptic automated chemistry production and quality control module for production of [(18)F]F(-) and clinical [(18)F]FDG. Performance, reliability, and safety of the system for the production of "dose on demand" were tested over several months. No-carrier-added [(18)F]F(-) was obtained through the (18)O(p,n)(18)F nuclear reaction by irradiation (20-40 min) of a >95% enriched [(18)O]H2O target (280 μl) with a 7.5-MeV proton beam (3.5-5.0 μA). Automated quality control tests were performed on each dose. The HPLC-based analytical methods were validated against USP methods of quality control. [(18)F]FDG produced by BG75 was tested in a mouse tumor model implanted with H441 human lung adenocarcinoma cells. After initial installment and optimization, the [(18)F]F(-) production has been consistent since March 2011 with a maximum production of 400 to 450 mCi in a day. The average yield is 0.61 mCi/min and 0.92 mCi/min at 3.8 µA and 5 µA, respectively. The current target window has held up for over 25 weeks against >400 bombardment cycles. [(18)F]FDG production has been consistent since June 2012 with an average of six doses/day in an automated synthesis mode (RCY≈50%). The release criteria included USP-specified limits for pH, residual solvents (acetonitrile/ethanol), kryptofix, radiochemical purity/identity, and filter integrity test. The entire automated operation generated minimal radiation exposure hazard to the operator and environment. As expected, [(18)F]FDG produced by BG75 was found to delineate tumor volume in a mouse model of xenograft tumor. In summary, production and quality control of "[(18)F]FDG dose on demand" have been accomplished in an automated and safe manner by the first Biomarker Generator. The implementation of a cGMP quality system is under way towards the ANDA submission and first clinical use of [(18)F]FDG produced by BG75.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
24650573
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"