EVALUATION STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Safety analysis of first 1000 patients treated with magnetic sphincter augmentation for gastroesophageal reflux disease.

Antireflux surgery with a magnetic sphincter augmentation device (MSAD) restores the competency of the lower esophageal sphincter with a device rather than a tissue fundoplication. As a regulated device, safety information from the published clinical literature can be supplemented by tracking under the Safe Medical Devices Act. The aim of this study was to examine the safety profile of the MSAD in the first 1000 implanted patients. We compiled safety data from all available sources as of July 1, 2013. The analysis included intra/perioperative complications, hospital readmissions, procedure-related interventions, reoperations, and device malfunctions leading to injury or inability to complete the procedure. Over 1000 patients worldwide have been implanted with the MSAD at 82 institutions with median implant duration of 274 days. Event rates were 0.1% intra/perioperative complications, 1.3% hospital readmissions, 5.6% endoscopic dilations, and 3.4% reoperations. All reoperations were performed non-emergently for device removal, with no complications or conversion to laparotomy. The primary reason for device removal was dysphagia. No device migrations or malfunctions were reported. Erosion of the device occurred in one patient (0.1%). The safety analysis of the first 1000 patients treated with MSAD for gastroesophageal reflux disease confirms the safety of this device and the implantation technique. The overall event rates were low based on data from 82 institutions. The MSAD is a safe therapeutic option for patients with chronic, uncomplicated gastroesophageal reflux disease.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app