Does stem design influence component positioning in total hip arthroplasty using a minimal invasive posterolateral approach?
International Orthopaedics 2014 July
PURPOSE: Limited data exist for the reconstructive potential of short bone-preserving stems in THA using a minimal invasive posterolateral approach. Our study aim was to assess the effect of stem design on the reconstruction of hip offset and leg length in MIS posterolateral THA.
METHODS: This retrospective consecutive single-surgeon study compares hip offset and leg length, as well as acetabular component positioning (cup anteversion; inclination) of 129 THAs with a cementless standard-length stem (Synergy®) and 143 THAs with a cementless short bone-preserving stem (Trilock®).
RESULTS: In reference to the contralateral side, the mean difference in hip offset was 0.9 mm (p = 0.067) for the standard stem and 0.1 mm (p = 0.793) for the short stem, respectively. Leg-length discrepancy was 0.7 mm (Synergy®) and 0.9 mm (Trilock®), respectively. A total of 233 (86 %) acetabular components fell within the target zone for anteversion and inclination.
CONCLUSION: Accurate component positioning in MIS posterolateral approach THA is possible and is not influenced by the type of stem.
METHODS: This retrospective consecutive single-surgeon study compares hip offset and leg length, as well as acetabular component positioning (cup anteversion; inclination) of 129 THAs with a cementless standard-length stem (Synergy®) and 143 THAs with a cementless short bone-preserving stem (Trilock®).
RESULTS: In reference to the contralateral side, the mean difference in hip offset was 0.9 mm (p = 0.067) for the standard stem and 0.1 mm (p = 0.793) for the short stem, respectively. Leg-length discrepancy was 0.7 mm (Synergy®) and 0.9 mm (Trilock®), respectively. A total of 233 (86 %) acetabular components fell within the target zone for anteversion and inclination.
CONCLUSION: Accurate component positioning in MIS posterolateral approach THA is possible and is not influenced by the type of stem.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app