JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Interrater and intrarater reliability of common clinical standing balance tests for people with hip osteoarthritis.

BACKGROUND: Hip osteoarthritis (OA) is a common musculoskeletal condition affecting older individuals. Clinical balance tests are frequently used to assess standing balance in these people. There is insufficient information regarding the reliability of these tests.

OBJECTIVE: The aim of this study was to estimate reliability and measurement error of 4 common clinical standing balance tests in people with hip OA.

DESIGN: A prospective study was conducted with repeated measures between 2 independent raters within 1 session and within 1 rater over a 1-week interval.

METHODS: Thirty people with hip OA were evaluated. Reliability was estimated for the Four-Square Step Test, Step Test, Functional Reach Test, and Timed Single-Leg Stance Test using intraclass correlation coefficients (ICC [2,1]). Measurement error was expressed as standard error of measurement and minimal detectable change.

RESULTS: The Four-Square Step Test, Step Test, and Timed Single-Leg Stance Test were sufficiently reliable between raters (ICC=.85-.94, lower 1-sided 95% confidence interval [95% CI]=.71-.89), whereas the Step Test (standing on study limb) and Timed Single-Leg Stance Test (standing on nonstudy limb) were sufficiently reliable within a rater over a 1-week interval (ICC=.91, lower 1-sided 95% CI=.80-.83). The Step Test (standing on study limb) and Timed Single-Leg Stance Test (standing on nonstudy limb) achieved optimal levels of reliability (ICC >.90, lower 1-sided 95% CI >.70), with acceptable measurement error (<10%) for clinical outcome measures. The Functional Reach Test was not sufficiently reliable. A ceiling effect was detected for the Timed Single-Leg Stance Test.

LIMITATIONS: Reliability was assessed only between 2 raters during a single session and within 1 rater over a 1-week interval, which limits generalizability.

CONCLUSIONS: The Step Test (standing on study limb) is recommended as a highly reliable test with acceptable measurement error for assessing standing balance in people with hip OA.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app