Late adverse events after implantation of sirolimus-eluting stent and bare-metal stent: long-term (5-7 years) follow-up of the Coronary Revascularization Demonstrating Outcome study-Kyoto registry Cohort-2.

BACKGROUND: Late adverse events such as very late stent thrombosis (VLST) or late target-lesion revascularization (TLR) after first-generation sirolimus-eluting stents (SES) implantation have not been yet fully characterized at long term in comparison with those after bare-metal stent (BMS) implantation.

METHODS AND RESULTS: Among 13 058 consecutive patients undergoing first percutaneous coronary intervention in the Coronary REvascularization Demonstrating Outcome study-Kyoto registry Cohort-2, 5078 patients were treated with SES only, and 5392 patients were treated with BMS only. During 7-year follow-up, VLST and late TLR beyond 1 year after SES implantation occurred constantly and without attenuation at 0.24% per year and at 2.0% per year, respectively. Cumulative 7-year incidence of VLST was significantly higher in the SES group than that in the BMS group (1.43% versus 0.68%, P<0.0001). However, there was no excess of all-cause death beyond 1 year in the SES group as compared with that in the BMS group (20.8% versus 19.6%, P=0.91). Cumulative incidences of late TLR (both overall and clinically driven) were also significantly higher in the SES group than in the BMS group (12.0% versus 4.1%, P<0.0001 and 8.5% versus 2.6%, P<0.0001, respectively), leading to late catch-up of the SES group to the BMS group regarding TLR through the entire 7-year follow-up (18.8% versus 25.2%, and 10.6% versus 10.2%, respectively). Clinical presentation as acute coronary syndrome was more common at the time of late SES TLR compared with early SES TLR (21.2% and 10.0%).

CONCLUSIONS: Late catch-up phenomenon regarding stent thrombosis and TLR was significantly more pronounced with SES than that with BMS. This limitation should remain the target for improvements of DES technology.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app