Add like
Add dislike
Add to saved papers

Correlation of echocardiographic and angiographic measurements of the pulmonary valve annulus in pulmonary stenosis.

OBJECTIVES: The pulmonary valve (PV) annulus is routinely measured angiographically in PV stenosis prior to balloon dilation. We sought to establish whether this radiation exposure is justified, or whether echocardiographic measurements prior to the procedure are sufficient to guide balloon selection.

BACKGROUND: Previous studies have found a strong correlation between echocardiographic and angiographic measurements of the PV annulus. However, error of measurement and its implication for procedural practice has not been explored.

METHODS: A total of 90 procedures in 84 patients were analyzed, at a median age 7.6 months (range 1 day to 14.2 years). The contemporaneous echocardiographic and angiographic measurements were recorded, and the original echocardiograms were re-measured in the 72 available cases by two independent reviewers.

RESULTS: There was a good correlation between the two measurement methods (R(2)  = 0.87). However, the echocardiographic PV measurements were smaller on average, with a significant variation in that discrepancy (mean ratio 0.941 (±0.16)). There was no significant reduction in error if extreme measurements (PV annulus z-score <-3) were excluded (P = 0.09), or if the reviewed echocardiographic measurements were used (P = 0.58).

CONCLUSIONS: There is an unacceptable discrepancy between the measurement techniques: 95% of patients are predicted to have an echocardiographic measurement error between -37% and +26%. Therefore, there is no correction factor that could be employed to allow safe selection of balloon size, and balloon pulmonary valvoplasty without angiographic PV measurement cannot be advocated.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app