Amplatzer PFO occluder device may prevent recurrent stroke in patients with patent foramen ovale and cryptogenic stroke: a meta-analysis of randomised trials.
Heart, Lung & Circulation 2014 April
OBJECTIVE: To review efficacy of percutaneous closure of patent foramen ovale compared with medical therapy in prevention of recurrent strokes in patients with cryptogenic stroke.
METHODS AND RESULTS: Electronic databases; PUBMED, EMBASE, Cochrane registry and web of knowledge were searched for relevant studies. In three randomised clinical trials involving 2303 participants, risk of the recurrent strokes (pooled HR 0.62, 95% CI=0.36-1.07, P=0.09, I(2) =10%) did not show benefit with device closure when compared with medical therapy group on meta-analysis of all three trials. However, on sensitivity analysis in trials using Amplatzer PFO occluder device, the closure of PFO was associated with significantly lower recurrent strokes (pooled HR=0.44, 95% CI=0.21-0.94, P=0.03, I(2)=0%) compared with medical therapy.
CONCLUSION: The closure of PFO with Amplatzer PFO occluder device was associated with significant reduction in recurrent strokes in patients with cryptogenic stroke and patent foramen ovale. The better outcome in prevention of secondary stroke in patients with cryptogenic stroke and PFO may be associated with type of closure device used.
METHODS AND RESULTS: Electronic databases; PUBMED, EMBASE, Cochrane registry and web of knowledge were searched for relevant studies. In three randomised clinical trials involving 2303 participants, risk of the recurrent strokes (pooled HR 0.62, 95% CI=0.36-1.07, P=0.09, I(2) =10%) did not show benefit with device closure when compared with medical therapy group on meta-analysis of all three trials. However, on sensitivity analysis in trials using Amplatzer PFO occluder device, the closure of PFO was associated with significantly lower recurrent strokes (pooled HR=0.44, 95% CI=0.21-0.94, P=0.03, I(2)=0%) compared with medical therapy.
CONCLUSION: The closure of PFO with Amplatzer PFO occluder device was associated with significant reduction in recurrent strokes in patients with cryptogenic stroke and patent foramen ovale. The better outcome in prevention of secondary stroke in patients with cryptogenic stroke and PFO may be associated with type of closure device used.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app