Temporal evolution of intraparenchymal hyperdensity after intra-arterial therapy in patients with ischemic stroke: optimal discrimination between hemorrhage and iodinated contrast.

PURPOSE: CT hyperattenuation arising from iodinated contrast has a different temporal evolution than that arising due to hemorrhage. This paper presents a method for optimal discrimination between hemorrhage and iodinated contrast in a postintervention CT in stroke patients.

METHODS: We analyzed the brain computed tomography (CT) scans of consecutive patients with intraparenchymal hyperattenuation due to hemorrhage (n=41), those due to iodinated contrast alone (n=24), and those due to contrast mixed with hemorrhage after reperfusion therapy (n=14) in stroke patients. The difference between the maximum enhancement in hyperattenuation in the affected area and the corresponding contralateral area, dubbed Relative Maximum Enhancement (RME), was tracked over time. We fitted regression models to the RME changes due to hemorrhage and contrast to describe their temporal decay, and then derived the optimal discriminant curve that distinguishes the two. A computer algorithm coregistered the baseline and follow-up CT scans and performed pixel-by-pixel comparison to determine hemorrhage and iodinated contrast based on the RME changes with respect to the discriminant curve.

RESULTS: For both hemorrhage (k= -0.004, R (2) =0.7) and iodinated contrast (k= -0.064, R (2)  =0.9), the temporal evolution of RMEs were best fitted by exponential decay curves, with respective half-lives of 192.3 and 10.7 h. An exponential decay model (k= -0.026) for optimal discrimination of hemorrhage vs. contrast was fitted. The computer algorithm implementing this model was successful in predicting the presence of hemorrhage in a hyperdense lesion with sensitivity =93% and specificity =91%.

CONCLUSION: Intraparenchymal hemorrhage and contrast have markedly different decay half-lives that can be used to assess hemorrhage in a hyperdense lesion on a CT scan after intra-arterial therapy.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app