A comparison of two systems of patient immobilization for prostate radiotherapy.

BACKGROUND: Reproducibility of different immobilization systems, which may affect set-up errors, remains uncertain. Immobilization systems and their corresponding set-up errors influence the clinical target volume to planning target volume (CTV-PTV) margins and thus may result in undesirable treatment outcomes. This study compared the reproducibility of patient positioning with Hipfix system and whole body alpha cradle with respect to localized prostate cancer and investigated the existing CTV-PTV margins in the clinical oncology departments of two hospitals.

METHODS: Forty sets of data of patients with localized T1-T3 prostate cancer were randomly selected from two regional hospitals, with 20 patients immobilized by a whole-body alpha cradle system and 20 by a thermoplastic Hipfix system. Seven sets of the anterior-posterior (AP), cranial-caudal (CC) and medial-lateral (ML) deviations were collected from each patient. The reproducibility of patient positioning within the two hospitals was compared using a total vector error (TVE) parameter. In addition, CTV-PTV margins were computed using van Herk's formula. The resulting values were compared to the current CTV-PTV margins in both hospitals.

RESULTS: The TVE values were 5.1 and 2.8 mm for the Hipfix and the whole-body alpha cradle systems respectively. TVE associated with the whole-body alpha cradle system was found to be significantly less than the Hipfix system (p < 0.05). The CC axis in the Hipfix system attained the highest frequency of large (23.6%) and serious (7.9%) set-up errors. The calculated CTV to PTV margin was 8.3, 1.9 and 2.3 mm for the Hipfix system, and 2.1, 3.4 and 1.8 mm for the whole body alpha cradle in CC, ML and AP axes respectively. All but one (CC axis using Hipfix) margin calculated did not exceed the corresponding hospital protocol. The whole body alpha cradle system was found to be significantly better than the Hipfix system in terms of reproducibility (p < 0.05), especially in the CC axis.

CONCLUSIONS: The whole body alpha cradle system was more reproducible than the Hipfix system. In particular, the difference in CC axis contributed most to the results and the current CC margin for the Hipfix system might be considered as inadequate.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app