We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Gastrojejunostomy by pure natural orifice transluminal endoscopic surgery using a newly designed anastomosing metal stent in a porcine model.
Surgical Endoscopy 2014 May
BACKGROUND: The accepted palliative treatment for malignant gastric outlet obstruction (GOO) is surgical bypass or placement of self-expandable metal stents. We developed a safe and simple natural orifice transluminal endoscopic surgery (NOTES) technique for gastrojejunostomy using a fully covered, anastomosing metal stent in a porcine model.
METHODS: Under general anesthesia, 11 pigs underwent gastrojejunostomy with a 4 cm length anastomosing metal stent. After gastrotomy formation using a needle knife, the jejunum was drawn into the stomach with alligator forceps. A jejunotomy was then performed in the gastric cavity, which was followed by deployment of an anastomosing metal stent under fluoroscopic guidance. Next, the first portion of the duodenum was resected by an endoscopic linear stapler via laparoscopy, thereby creating the model of GOO. Oral feeding was resumed 24 h after the procedure, and animals were euthanized at 1, 2, and 4 weeks after the operation.
RESULTS: Side-to-side gastrojejunostomy was successfully completed through NOTES in 10/11 animals. Ten pigs stayed healthy until the planned sacrifice. The mean gastrojejunostomy procedure time was 41 min (range 15-94 min). By postmortem examination, anastomoses were still intact without intraperitoneal necrosis or adhesion. Histological examination revealed adequate submucosal apposition in all ten experimental pigs undergoing successful endoscopic gastrojejunostomy.
CONCLUSION: Creating a gastrojejunostomy by NOTES using an anastomosing metal stent seems to be a safe, feasible, durable, and reproducible method for GOO.
METHODS: Under general anesthesia, 11 pigs underwent gastrojejunostomy with a 4 cm length anastomosing metal stent. After gastrotomy formation using a needle knife, the jejunum was drawn into the stomach with alligator forceps. A jejunotomy was then performed in the gastric cavity, which was followed by deployment of an anastomosing metal stent under fluoroscopic guidance. Next, the first portion of the duodenum was resected by an endoscopic linear stapler via laparoscopy, thereby creating the model of GOO. Oral feeding was resumed 24 h after the procedure, and animals were euthanized at 1, 2, and 4 weeks after the operation.
RESULTS: Side-to-side gastrojejunostomy was successfully completed through NOTES in 10/11 animals. Ten pigs stayed healthy until the planned sacrifice. The mean gastrojejunostomy procedure time was 41 min (range 15-94 min). By postmortem examination, anastomoses were still intact without intraperitoneal necrosis or adhesion. Histological examination revealed adequate submucosal apposition in all ten experimental pigs undergoing successful endoscopic gastrojejunostomy.
CONCLUSION: Creating a gastrojejunostomy by NOTES using an anastomosing metal stent seems to be a safe, feasible, durable, and reproducible method for GOO.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app