JOURNAL ARTICLE

Use of a novel diagonal pump in an in vitro neonatal pulsatile extracorporeal life support circuit

Alissa Evenson, Shigang Wang, Allen R Kunselman, Akif Ündar
Artificial Organs 2014, 38 (1): E1-9
24372027
One approach with the potential to improve morbidity and mortality rates following extracorporeal life support (ECLS) is the use of pulsatile perfusion. Currently, no ECLS pumps used in the United States can produce pulsatile flow. The objective of this experiment is to evaluate a novel diagonal pump used in Europe to determine whether it provides physiological pulsatility in a neonatal model. The ECLS circuit consisted of a Medos Deltastream DP3 diagonal pump, a Hilite 800LT polymethylpentene diffusion membrane oxygenator, and arterial/venous tubing. A 300-mL pseudopatient was connected to the circuit using an 8Fr arterial cannula and a 10Fr venous cannula. A clamp maintained constant pressure entering the pseudopatient. Trials (64 total) were conducted in nonpulsatile and pulsatile modes at flow rates of 200 mL/min to 800 mL/min. Flow and pressure data were collected using a custom-based data acquisition system. The Deltastream DP3 pump was capable of producing an adequate quality of pulsatility. Pulsatile flow produced increased mean arterial pressure, energy equivalent pressure (EEP), and surplus hemodynamic energy (SHE) at all flow rates compared to nonpulsatile flow. Pressure drop across the cannula accounted for the majority of pressure loss in the circuit. The greatest loss of SHE and total hemodynamic energy occurred across the arterial cannula due to its small diameter. The Deltastream DP3 pump produced physiological pulsatile flow without backflow while providing EEP and SHE to our neonatal pseudopatient. Further experiments are necessary to determine the impact of this pulsatile pump in an in vivo model prior to clinical use.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
24372027
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"