Localization accuracy and immobilization effectiveness of a stereotactic body frame for a variety of treatment sites.

PURPOSE: The purpose of this study was to analyze the pretreatment setup errors and intrafraction motion using cone beam computed tomography (CBCT) for stereotactic body radiation therapy patients immobilized and localized with a stereotactic body frame for a variety of treatment sites.

METHODS AND MATERIALS: Localization errors were recorded for patients receiving SBRT for 141 lung, 29 liver, 48 prostate, and 45 spine tumors representing 1005 total localization sessions. All patients were treated in a stereotactic body frame with a large custom-molded vacuum pillow. Patients were first localized to the frame using tattoos placed during simulation. Subsequently, the frame was aligned to the room lasers according to the stereotactic coordinates determined from the treatment plan. Every patient received a pretreatment and an intrafraction CBCT. Abdominal compression was used for all liver patients and for approximately 40% of the lung patients to reduce tumor motion due to respiration.

RESULTS: The mean ± standard deviation pretreatment setup errors from all localizations were -2.44 ± 3.85, 1.31 ± 5.84, and 0.11 ± 3.76 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean pretreatment localization results among all treatment sites were not significantly different (F test, P<.05). For all treatment sites, the mean ± standard deviation intrafraction shifts were 0.33 ± 1.34, 0.15 ± 1.45, and -0.02 ± 1.17 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean unidimensional intrafraction shifts were statistically different for several of the comparisons (P<.05) as assessed by the Tukey-Kramer test.

CONCLUSIONS: Despite the varied tumor locations, the pretreatment mean localization errors for all sites were found to be consistent among the treatment sites and not significantly different, indicating that the body frame is a suitable immobilization and localization device for a variety of tumor sites. Our pretreatment localization errors and intrafraction shifts compare favorably with those reported in other studies using different types of immobilization devices.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app