Concomitant transapical treatment of aortic stenosis and degenerated mitral bioprosthesis with two 29 mm Edwards Sapien XT prostheses.
Journal of Invasive Cardiology 2013 December
An 85-year-old woman was admitted to our institution for effort dyspnea. She had a history of mitral valve replacement with a 29 mm Carpentier-Edwards bioprosthesis (Edwards Lifesciences). Transthoracic echocardiography (TTE) showed aortic stenosis and senescence of the mitral bioprosthesis. The heart team opted for a transapical transcatheter aortic valve implantation (TAVI) and mitral valve-in-valve implantation (m-ViV). Two Edwards Sapien XT (ESXT) 29 mm devices were selected. To our knowledge, this is the first description of the concomitant transapical implantation of two 29 mm ESXTs for a combination of failed mitral bioprosthesis and native aortic stenosis.