Relationship between biomechanical changes at adjacent segments and number of fused bone grafts in multilevel cervical fusions: a finite element investigation.
Journal of Neurosurgery. Spine 2014 January
OBJECT: Biomechanical studies have shown that anterior cervical fusion construct stiffness and arthrodesis rates vary with different reconstruction techniques; however, the behavior of the adjacent segments in the setting of different procedures is poorly understood. This study was designed to investigate the adjacent-segment biomechanics after 3 different anterior cervical decompression and fusion techniques, including 3-level discectomy and fusion, 2-level corpectomy and fusion, and a corpectomy-discectomy hybrid technique. The authors hypothesized that biomechanical changes at the segments immediately superior and inferior to the multilevel fusion would be inversely proportional to the number of fused bone grafts and that these changes would be related to the type of fusion technique.
METHODS: A previously validated 3D finite element model of an intact C3-T1 segment was used. Three C4-7 fusion models were built from this intact model by varying the number of bone grafts used to span the decompression: a 1-graft model (2-level corpectomy), a 2-graft model (C-5 corpectomy and C6-7 discectomy), and a 3-graft model (3-level discectomy). The corpectomy and discectomy models were also previously validated and compared well with the literature findings. Range of motion, disc stresses, and posterior facet loads at the segments superior (C3-4) and inferior (C7-T1) to the fusion construct were assessed.
RESULTS: Motion, disc stresses, and posterior facet loads generally increased at both of the adjacent segments in relation to the intact model. Greater biomechanical changes were noted in the superior C3-4 segment than in the inferior C7-T1 segment. Increasing the number of bone grafts from 1 to 2 and from 2 to 3 was associated with a lower magnitude of biomechanical changes at the adjacent segments.
CONCLUSIONS: At segments adjacent to the fusion level, biomechanical changes are not limited solely to the discs, but also propagate to the posterior facets. These changes in discs and posterior facets were found to be lower for discectomy than for corpectomy, thereby supporting the current study hypothesis of inverse relationship between the adjacent-segment variations and the number of fused bone grafts. Such changes may go on to influence the likelihood of adjacent-segment degeneration accordingly. Further studies are warranted to identify the causes and true impact of these observed changes.
METHODS: A previously validated 3D finite element model of an intact C3-T1 segment was used. Three C4-7 fusion models were built from this intact model by varying the number of bone grafts used to span the decompression: a 1-graft model (2-level corpectomy), a 2-graft model (C-5 corpectomy and C6-7 discectomy), and a 3-graft model (3-level discectomy). The corpectomy and discectomy models were also previously validated and compared well with the literature findings. Range of motion, disc stresses, and posterior facet loads at the segments superior (C3-4) and inferior (C7-T1) to the fusion construct were assessed.
RESULTS: Motion, disc stresses, and posterior facet loads generally increased at both of the adjacent segments in relation to the intact model. Greater biomechanical changes were noted in the superior C3-4 segment than in the inferior C7-T1 segment. Increasing the number of bone grafts from 1 to 2 and from 2 to 3 was associated with a lower magnitude of biomechanical changes at the adjacent segments.
CONCLUSIONS: At segments adjacent to the fusion level, biomechanical changes are not limited solely to the discs, but also propagate to the posterior facets. These changes in discs and posterior facets were found to be lower for discectomy than for corpectomy, thereby supporting the current study hypothesis of inverse relationship between the adjacent-segment variations and the number of fused bone grafts. Such changes may go on to influence the likelihood of adjacent-segment degeneration accordingly. Further studies are warranted to identify the causes and true impact of these observed changes.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app