JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Quality by Design approach in the development of a solvent-modified micellar electrokinetic chromatography method: finding the design space for the determination of amitriptyline and its impurities.

Analytica Chimica Acta 2013 November 14
A solvent-modified micellar electrokinetic chromatography method was set up for the simultaneous determination of the tricyclic antidepressant amitriptyline (AMI) and its main impurities. The method was developed following Quality by Design (QbD) principles according to ICH Guideline Q8(R2). QbD approach made it possible to find the design space (DS), where quality was assured. After a scouting phase, aimed at selecting a suitable capillary electrophoresis pseudostationary phase, risk assessment tools were employed to define the critical process parameters (CPPs) to be considered in a screening phase (applied voltage, concentration and pH of the background electrolyte, concentration of the surfactant sodium dodecyl sulphate, of the cosurfactant n-butanol and of the organic modifiers acetonitrile and urea). The effects of the seven selected CPPs on critical quality attributes (CQAs), namely resolution values between critical peak pairs and analysis time, were investigated throughout the knowledge space by means of a symmetric screening matrix. Response surface study was then carried out on four selected CPPs by applying a Doehlert Design. Monte-Carlo simulations were performed in order to estimate the probability of meeting the desired specifications on CQAs, and thus to define the DS by means of a risk of failure map. Additional points at the edges of the DS were tested in order to verify the requirements for CQAs to be fulfilled. A control strategy was implemented by defining system suitability tests. The developed method was validated following ICH Guideline Q2(R1), including robustness assessment by Plackett-Burman design, and was applied to the analysis of real samples of amitriptyline coated tablets.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app