Sustained life-like waveform capnography after human cadaveric tracheal intubation.
Emergency Medicine Journal : EMJ 2015 March
INTRODUCTION: Fresh frozen cadavers are effective training models for airway management. We hypothesised that residual carbon dioxide (CO2) in cadaveric lung would be detectable using standard clinical monitoring systems, facilitating detection of tracheal tube placement and further enhancing the fidelity of clinical simulation using a cadaveric model.
METHODS: The tracheas of two fresh frozen unembalmed cadavers were intubated via direct laryngoscopy. Each tracheal tube was connected to a self-inflating bag and a sidestream CO2 detector. The capnograph display was observed and recorded in high-definition video. The cadavers were hand-ventilated with room air until the capnometer reached zero or the waveform approached baseline.
RESULTS: A clear capnographic waveform was produced in both cadavers on the first postintubation expiration, simulating the appearances found in the clinical setting. In cadaver one, a consistent capnographic waveform was produced lasting over 100 s. Maximal end-tidal CO2 was 8.5 kPa (65 mm Hg). In cadaver two, a consistent capnographic waveform was produced lasting over 50 s. Maximal end-tidal CO2 was 5.9 kPa (45 mm Hg).
CONCLUSIONS: We believe this to be the first work to describe and quantify detectable end-tidal capnography in human cadavers. We have demonstrated that tracheal intubation of fresh frozen cadavers can be confirmed by life-like waveform capnography. This requires further validation in a larger sample size.
METHODS: The tracheas of two fresh frozen unembalmed cadavers were intubated via direct laryngoscopy. Each tracheal tube was connected to a self-inflating bag and a sidestream CO2 detector. The capnograph display was observed and recorded in high-definition video. The cadavers were hand-ventilated with room air until the capnometer reached zero or the waveform approached baseline.
RESULTS: A clear capnographic waveform was produced in both cadavers on the first postintubation expiration, simulating the appearances found in the clinical setting. In cadaver one, a consistent capnographic waveform was produced lasting over 100 s. Maximal end-tidal CO2 was 8.5 kPa (65 mm Hg). In cadaver two, a consistent capnographic waveform was produced lasting over 50 s. Maximal end-tidal CO2 was 5.9 kPa (45 mm Hg).
CONCLUSIONS: We believe this to be the first work to describe and quantify detectable end-tidal capnography in human cadavers. We have demonstrated that tracheal intubation of fresh frozen cadavers can be confirmed by life-like waveform capnography. This requires further validation in a larger sample size.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app