Time for a paradigm shift with computerized adaptive testing of general physical function outcomes measurements.
Foot & Ankle International 2014 January
BACKGROUND: Patient-reported outcomes (PRO) are critical to understanding the value of orthopedic treatments. We hypothesized that use of the computerized adaptive testing from a well-characterized physical function item bank would show superiority in assessing all levels of physical function compared to current standard generic physical function outcomes instruments for foot and ankle patients.
METHODS: In a population of 126 foot and ankle patients we compared the psychometric properties for three PROs: the Physical Function subscale of the Medical Outcomes General Health Survey (SF-36 PF) version 2, the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) Computerized Adaptive Test (CAT), and the Lower Extremity (LE) CAT. A Rasch item response theory (IRT) model was applied to assess and compare the fit, dimensionality, reliability, validity, and coverage.
RESULTS: The unexplained variance for the PF CAT was 3.9% and the LE CAT was 2.1%, suggesting each instrument explained a single concept. The SF-36 PF had more concerning unexplained variance of 7.6%. We found no floor or ceiling effects for the PF CAT, a minimal floor effect (1.6%) but no ceiling effect for the LE CAT, and an 11.1% floor effect and 9.5% ceiling effect for the SF-36 PF.
CONCLUSION: Foot and ankle clinicians and researchers interested in measuring patient perceived functional outcomes with a generic instrument should consider using either the PF CAT or the LE CAT rather than the SF-36 PF. Further studies comparing these CATs to anatomic specific instruments are needed.
LEVEL OF EVIDENCE: Level I, diagnostic study.
METHODS: In a population of 126 foot and ankle patients we compared the psychometric properties for three PROs: the Physical Function subscale of the Medical Outcomes General Health Survey (SF-36 PF) version 2, the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) Computerized Adaptive Test (CAT), and the Lower Extremity (LE) CAT. A Rasch item response theory (IRT) model was applied to assess and compare the fit, dimensionality, reliability, validity, and coverage.
RESULTS: The unexplained variance for the PF CAT was 3.9% and the LE CAT was 2.1%, suggesting each instrument explained a single concept. The SF-36 PF had more concerning unexplained variance of 7.6%. We found no floor or ceiling effects for the PF CAT, a minimal floor effect (1.6%) but no ceiling effect for the LE CAT, and an 11.1% floor effect and 9.5% ceiling effect for the SF-36 PF.
CONCLUSION: Foot and ankle clinicians and researchers interested in measuring patient perceived functional outcomes with a generic instrument should consider using either the PF CAT or the LE CAT rather than the SF-36 PF. Further studies comparing these CATs to anatomic specific instruments are needed.
LEVEL OF EVIDENCE: Level I, diagnostic study.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app