PURPOSE: To assess the role of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of patients with suspicion of multiple myeloma (MM).

MATERIALS AND METHODS: A total of 138 patients (76 male and 62 female; mean age 63.5 years, range 50-81 years), with early MM, underwent WBLDCT protocol study, performed on 16-slice scanner (Brilliance, Philips Medical System, Eindhoven, The Netherlands): tube voltage 120 kV; tube current time product 40 mAs. Diagnosis of osteolytic lesions was performed on the basis of axial and multiplanar reformatted images, whereas the assessment of spinal misalignment and fracture was done by using multiplanar reformatted images. The overall dose delivered to each patient was 4.2 mSv. Every patient gave personal informed consent, as required by our institution guidelines.

RESULTS: The diagnosis was established either by histopathology or imaging follow-up (size increase of over a period time). In all 138 patients, image resolution was diagnostic, enabling correct classification of multiple myeloma patients. WBLDCT showed a total of 328 pathologic bone findings in 81/138 patients. CT scanning resulted in complete evaluation of the bone lesions in these areas of the skeleton: skull (42), humerus (15), femur (20), ribs (7), scapulae (13), pelvis (35), clavicle (13), sternum (10), cervical (39), dorsal (65), lombar (48) and sacral rachis (21). In 40/81 bone involvement detected by CT was the only CRAB criterion present. Furthermore, WBLDCT demonstrated pleuro-pulmonary lesions in 20 patients (11 infective, 9 as MM localizations) and 1 renal neoplasia.

CONCLUSION: WBLDCT, detecting bone marrow localizations and demonstrating extra-osseous findings, with a fast scanning time and high resolution images, is a reliable imaging-based tool for a proper management of MM patients.

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
24074647
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"