COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY

Prosthesis failure within 2 years of implantation is highly predictive of infection

María Eugenia Portillo, Margarita Salvadó, Albert Alier, Lluisa Sorli, Santos Martínez, Juan Pablo Horcajada, Lluis Puig
Clinical Orthopaedics and related Research 2013, 471 (11): 3672-8
23904245

BACKGROUND: The outcome of revision surgery depends on accurate determination of the cause of prosthesis failure because treatment differs profoundly among aseptic loosening, mechanical failure, and prosthetic joint infections (PJI).

QUESTIONS/PURPOSES: We sought to determine (1) the predictive role of the interval from primary to revision surgery in determining the reason for prosthesis failure of a hip, knee, shoulder, or elbow arthroplasty, and (2) whether positive cultures during revision surgery for aseptic loosening were associated with shorter event-free survival of the prosthesis.

METHODS: All patients undergoing revision surgery between July 2010 and January 2012 were included in a prospective cohort of 112 patients, and were classified as having had failure from aseptic loosening (56%), mechanical failure (15%), or PJI (29%). To make the diagnosis of PJI, at surgery we used a standardized enhanced diagnostic approach in all patients including sampling of five periprosthetic tissue specimens, sonication of removed prosthetic components, prolonged incubation of aerobic and anaerobic cultures, and multiplex PCR of sonication fluid in aseptic loosening cases. Kaplan-Meier survival and Cox proportional hazards regression analysis were performed.

RESULTS: The median time from primary to revision surgery was (p < 0.001) longer for patients with aseptic loosening (7.8 years) than for patients with mechanical failure (1.6 years) or PJI (2 years). No difference in the time to revision was observed for patients with aseptic loosening with positive or negative microbiological cultures (p = 0.594). Propionibacterium acnes was cultured below the established microbiological criteria for positivity in 12 (19%) procedures that had been presumed to have been revisions for aseptic loosening.

CONCLUSIONS: PJI should be considered in all revisions performed within 2 years of implantation even in the absence of clinical or laboratory findings suggestive for infection. However, the growth of low-virulence microorganisms below the cut-off in revisions for apparent aseptic loosening is not associated with early prosthesis failure.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
23904245
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"