Fiducial markers for image-guided partial breast irradiation.
La Radiologia Medica 2013 October
PURPOSE: This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers.
MATERIALS AND METHODS: Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student's t test was used to detect a meaningful difference of 3 mm in between the two methods.
RESULTS: A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs. 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs. 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs. 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm (p=0.001), 3 mm [p=not significant (ns)], and 3 mm (p=ns), respectively.
CONCLUSIONS: Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.
MATERIALS AND METHODS: Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student's t test was used to detect a meaningful difference of 3 mm in between the two methods.
RESULTS: A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs. 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs. 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs. 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm (p=0.001), 3 mm [p=not significant (ns)], and 3 mm (p=ns), respectively.
CONCLUSIONS: Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app