Foley catheter or prostaglandin E2 inserts for induction of labour at term: an open-label randomized controlled trial (PROBAAT-P trial) and systematic review of literature

Marta Jozwiak, Katrien Oude Rengerink, Mieke L G Ten Eikelder, Maria G van Pampus, Marja G K Dijksterhuis, Irene M de Graaf, Joris A M van der Post, Paulien van der Salm, Hubertina C J Scheepers, Nico Schuitemaker, Jan Willem de Leeuw, Ben W J Mol, Kitty W M Bloemenkamp
European Journal of Obstetrics, Gynecology, and Reproductive Biology 2013, 170 (1): 137-45
23870188

OBJECTIVE: To assess the safety and effectiveness of a transcervical Foley catheter compared to vaginal prostaglandin E2 inserts for term induction of labour.

STUDY DESIGN: We conducted an open-label randomized controlled trial in five hospitals in the Netherlands. Women with a singleton term pregnancy in cephalic presentation, intact membranes, unfavourable cervix, and no prior caesarean section were enrolled. Participants were randomly allocated by a web-based randomization system to induction of labour with a 30 ml Foley catheter or 10mg slow-release vaginal prostaglandin E2 inserts in a 1:1 ratio. Due to the nature of the intervention this study was not blinded. The primary outcome was the caesarean section rate. Secondary outcomes were maternal and neonatal morbidity and time from intervention to birth. Additionally, we carried out a systematic review and meta-analysis of similar studies.

RESULTS: We analyzed 226 women: 107 received a Foley catheter and 119 inserts. Caesarean section rates were comparable (20% versus 22%, RR 0.90, 95% CI 0.54-1.50). Secondary outcomes showed no differences. We observed no serious maternal or neonatal morbidity. Meta-analysis showed comparable caesarean section rates, but significantly fewer cases of hyperstimulation during the ripening phase when a Foley catheter was used.

CONCLUSIONS: We found, in this relatively small study, no differences in effectiveness and safety of induction of labour with a Foley catheter and 10mg slow release vaginal prostaglandin E2 inserts. Meta-analysis confirmed a comparable caesarean section rate, and showed fewer cases of hyperstimulation when a Foley catheter was used.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
23870188
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"