JOURNAL ARTICLE

Proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography applied for tricuspid regurgitation quantification

Jose Alberto de Agustin, Dafne Viliani, Catarina Vieira, Fabian Islas, Pedro Marcos-Alberca, Jose Juan Gomez de Diego, Ivan Javier Nuñez-Gil, Carlos Almeria, Jose Luis Rodrigo, Maria Luaces, Miguel Angel Garcia-Fernandez, Carlos Macaya, Leopoldo Perez de Isla
Journal of the American Society of Echocardiography 2013, 26 (9): 1063-72
23860094

BACKGROUND: The two-dimensional (2D) proximal isovelocity surface area (PISA) method has known technical limitations, mainly the geometric assumptions of PISA shape required to calculate effective regurgitant orifice area (EROA). Recently developed single-beat real-time three-dimensional (3D) color Doppler imaging allows the direct measurement of PISA without geometric assumptions and has already been validated for mitral regurgitation assessment. The aim of this study was to apply this novel method in patients with chronic tricuspid regurgitation (TR).

METHODS: Ninety patients with chronic TR were enrolled. EROA and regurgitant volume (Rvol) were assessed using transthoracic 2D and 3D PISA methods. Quantitative Doppler and 3D transthoracic planimetry of EROA were used as reference methods.

RESULTS: Both EROA and Rvol assessed using the 3D PISA method had better correlations with the reference methods than using conventional 2D PISA, particularly in the assessment of eccentric jets. On the basis of 3D planimetry-derived EROA, 35 patients had severe TR (EROA ≥ 0.4 cm(2)). Among these 35 patients, 25.7% (n = 9) were underestimated as having nonsevere TR (EROA ≤ 0.4 cm(2)) using the 2D PISA method. In contrast, the 3D PISA method had 94.3% agreement (33 of 35) with 3D planimetry in classifying severe TR. Good intraobserver and interobserver agreement for 3D PISA measurements was observed, with intraclass correlation coefficients of 0.92 and 0.88 respectively.

CONCLUSIONS: TR quantification using PISA by single-beat real-time 3D color Doppler echocardiography is feasible in the clinical setting and more accurate than the conventional 2D PISA method.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
23860094
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"