Journal Article
Validation Studies
Add like
Add dislike
Add to saved papers

Validation of a proposed warfarin dosing algorithm based on the genetic make-up of Egyptian patients.

BACKGROUND: Warfarin is the most frequently prescribed oral anticoagulant worldwide. Due to its narrow therapeutic index and inter-patient variability in dose requirement, this drug has been considered an ideal target for personalised medicine. Several warfarin dosing algorithms have been proposed to tailor the warfarin dosage in the European, Asian and African-American populations. However, minimal interest was directed towards Middle East countries. The factors affecting warfarin dose requirement could be different in patients from different geographical and ethnic groups, limiting the value of published dosing algorithms.

OBJECTIVE: The first objective of this study was to examine the contribution of genetic and nongenetic factors on the variability of warfarin dose requirements in the Egyptian population using an easy, cost-effective and rapid analysis of vitamin K epoxide reductase complex subunit 1 (VKORC1) and cytochrome P450 (CYP) 2C9 single nucleotide polymorphism (SNP) genotyping of patients. A second objective was to develop and validate an algorithm for warfarin dose prediction that is tailored to Egyptian patients.

METHODS: Eighty-four patients, 41 males and 43 females, with a median (25th-75th percentiles) age of 39 (31-48) years were recruited in this study. Fifty patients whose international normalised ratio (INR) was in the range of 2-3 were allocated to a study cohort. SYBR Green-based multiplex allele-specific real-time PCR was used for genotyping of CYP2C9 (1075A>C) and VKORC1 (1173C>T) polymorphisms. Linear regression analysis, including the variables age, gender, CYP2C9 and VKORC1 SNP genotypes, was run to derive the best model for estimating the warfarin dose that achieves an INR of 2-3. The new warfarin dosing algorithm was examined in a second cohort of patients (n=34) to check its validity. The predicted dose requirements for a subgroup of our patients were calculated according to Gage and International Warfarin Pharmacogenetics Consortium (IWPC) algorithms available at https://www.warfarindosing.org.

RESULTS: In the study cohort, warfarin dose/week in VKORC1 TT subjects was statistically significantly lower than in VKORC1 CC/CT subjects (p=0.032), while there was no statistically significant difference in warfarin dose/week between CYP2C9*1*1 and *1*3 (p=0.925). A multivariate stepwise linear regression analysis revealed that age and VKORC1 had independent and significant contributions to the overall variability in warfarin dose with a p-value=0.013 and 0.042, respectively. Maintenance dose (mg/week)=65.226-0.422×(age) - 9.474×(VKORC1). The estimated regression equation was able to account for 20.5% of the overall variability in warfarin maintenance dose. A significant positive correlation, with sufficient strength, was observed between the predicted warfarin dose and the actual prescribed dose (r=0.453, p=0.001). In the validation cohort, after application of the dosing algorithm, correlation between predicted and actual dose was statistically significant (p=0.023). The equation was particularly successful among patients with a dose≥35 mg/week. The correlation coefficient between the actual and predicted doses for IWPC and Gage were 0.304 and 0.276, respectively. When compared with our algorithm (r=0.279), the difference was non-significant: p=0.903 and 0.990, respectively.

CONCLUSION: VKORC1 (1173C>T) contributes to the warfarin dose variability. Patients' age and genetic variants of VKORC1 account for nearly 20.5% of the variability in warfarin dose required to achieve an INR of 2-3. The success of a prediction equation based on these variables was proved in a different cohort: the predicted dose correlated significantly with the maintenance dose and the equation was more successful among patients with a dose≥35 mg/week. The results of the warfarin algorithm we developed were comparable with those of the IWPC and Gage algorithms with the advantage of using one SNP (VKORC1 1173C>T) only. This represents an economic advantage in our community. Replication of this study in a larger cohort of patients is necessary before translation of this knowledge into clinical guidelines for warfarin prescription.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app