Central auditory maturation and behavioral outcome in children with auditory neuropathy spectrum disorder who use cochlear implants.
International Journal of Audiology 2013 September
OBJECTIVE: We examined cortical auditory development and behavioral outcomes in children with ANSD fitted with cochlear implants (CI).
DESIGN: Cortical maturation, measured by P1 cortical auditory evoked potential (CAEP) latency, was regressed against scores on the infant toddler meaningful auditory integration scale (IT-MAIS). Implantation age was also considered in relation to CAEP findings.
STUDY SAMPLE: Cross-sectional and longitudinal samples of 24 and 11 children, respectively, with ANSD fitted with CIs.
RESULTS: P1 CAEP responses were present in all children after implantation, though previous findings suggest that only 50-75% of ANSD children with hearing aids show CAEP responses. P1 CAEP latency was significantly correlated with participants' IT-MAIS scores. Furthermore, more children implanted before age two years showed normal P1 latencies, while those implanted later mainly showed delayed latencies. Longitudinal analysis revealed that most children showed normal or improved cortical maturation after implantation.
CONCLUSION: Cochlear implantation resulted in measureable cortical auditory development for all children with ANSD. Children fitted with CIs under age two years were more likely to show age-appropriate CAEP responses within six months after implantation, suggesting a possible sensitive period for cortical auditory development in ANSD. That CAEP responses were correlated with behavioral outcome highlights their clinical decision-making utility.
DESIGN: Cortical maturation, measured by P1 cortical auditory evoked potential (CAEP) latency, was regressed against scores on the infant toddler meaningful auditory integration scale (IT-MAIS). Implantation age was also considered in relation to CAEP findings.
STUDY SAMPLE: Cross-sectional and longitudinal samples of 24 and 11 children, respectively, with ANSD fitted with CIs.
RESULTS: P1 CAEP responses were present in all children after implantation, though previous findings suggest that only 50-75% of ANSD children with hearing aids show CAEP responses. P1 CAEP latency was significantly correlated with participants' IT-MAIS scores. Furthermore, more children implanted before age two years showed normal P1 latencies, while those implanted later mainly showed delayed latencies. Longitudinal analysis revealed that most children showed normal or improved cortical maturation after implantation.
CONCLUSION: Cochlear implantation resulted in measureable cortical auditory development for all children with ANSD. Children fitted with CIs under age two years were more likely to show age-appropriate CAEP responses within six months after implantation, suggesting a possible sensitive period for cortical auditory development in ANSD. That CAEP responses were correlated with behavioral outcome highlights their clinical decision-making utility.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app