Impact of iodine delivery rate with varying flow rates on image quality in dual-energy CT of patients with suspected pulmonary embolism.

Academic Radiology 2013 August
RATIONALE AND OBJECTIVES: To prospectively compare four contrast material injection protocols for dual-energy computed tomography (CT) pulmonary angiography (DE-CTPA) in patients with suspected pulmonary embolism (PE).

MATERIALS AND METHODS: One hundred twenty consecutive patients were randomized to contrast material injection protocols defined by different iodine concentrations and iodine delivery rates (IDRs): (A) 80 mL iopromide 370/4 mL/sec = IDR 1.4 gI/sec; (B) 80 mL iopromide 370 at 3 mL/sec = IDR 1.1 gI/sec; (C) 98 mL iopromide 300 at 4.9 mL/sec = IDR 1.4 gI/sec; and (D) 98 mL iopromide 300 at 3.7 mL/sec = IDR 1.1 gI/sec. Attenuation values were measured in the inflow tract (subclavian vein-superior vena cava-right atrium), target tract (right ventricle-pulmonary trunk-pulmonary arteries), and outflow tract (left atrium-left ventricle-ascending aorta). Two readers assessed subjective image quality of CTPA images and iodine perfusion maps. The number of artifacts due to hyperdense contrast material on iodine perfusion maps was recorded.

RESULTS: Target tract attenuation was highest for protocol A with 374 ± 98 Hounsfield units (HU) (highly concentrated contrast material/high IDR). This was significant compared to protocols B and D (P = .0118, P = .0427) but not compared to protocol C (P = .3395). No significant difference in target tract attenuation was found between protocols B (309 ± 80 HU), protocol C (352 ± 119 HU), and D (325 ± 74 HU). CTPA and iodine perfusion map image quality for protocol A was rated significantly higher compared to all other protocols (median score = 5/4; P < .0001 for both) with moderate interreader agreement (κ = 0.58/0.47). Protocols A and B displayed increased artifacts on iodine perfusion maps compared to protocols C and D (3 versus 2).

CONCLUSION: Despite increased artifacts on iodine perfusion maps, highly concentrated iodinated contrast material combined with high flow rates provides improved diagnostic image quality and has the highest target-tract attenuation for DE-CTPA protocols.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app