JOURNAL ARTICLE
REVIEW
Add like
Add dislike
Add to saved papers

Blood lactate concentration after exposure to conducted energy weapons (including TASER® devices): is it clinically relevant?

In previous studies, blood lactate concentration (BLac) consistently increased in anesthetized animals and in human subjects after exposures to TASER(®) conducted energy weapons (CEWs). Some have suggested the increased BLac would have detrimental consequences. In the current review, the following are evaluated: (a) the nature of muscle contractions due to CEWs, (b) general aspects of increased BLac, (c) previous studies of conventional neuromuscular electrical stimulation and CEW exposures, and (d) BLac in disease states. On the basis of these analyses, one can conclude that BLac, per se (independent of acidemia), would not be clinically relevant immediately after short-duration CEW applications, due to the short time course of any increase.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app