A comparison of the femoral and radial crossover techniques for vascular access management in transcatheter aortic valve implantation: the Milan experience.
Catheterization and Cardiovascular Interventions 2014 January 2
OBJECTIVE: To compare radial and femoral crossover techniques (CT) for vascular access management in transcatheter aortic valve implantation (TAVI).
BACKGROUND: Femoral crossover for controlled angiography and balloon inflation of the therapeutic access site to facilitate safe vascular closure is beneficial but technically challenging in patients with complex femoral anatomy. An alternative approach should be available.
METHODS: Between June 2011 and March 2012, 41 transfemoral TAVI patients receiving the femoral CT were compared to 46 transfemoral TAVI patients receiving the radial CT. Outcomes were 30-day valve academic research consortium (VARC) endpoints.
RESULTS: Patients undergoing the radial CT received higher median contrast volumes (150 interquartile range [IQR]: 105-180 vs. 111 IQR: 90-139 ml; P = 0.025) but procedural radiation dose and fluoroscopy times were comparable. Thirty day all cause and cardiovascular death were similar between radial and femoral CT groups (respectively 2.4% vs. 7.9%, P = 0.258 and 0% vs. 7.9%, P = 0.063). There were no differences in major vascular complications (4.3% vs. 7.3%, P = 0.553), life threatening or major bleeding events (respectively 9.1% vs. 19.5%, P = 0.168 and 13.6% vs. 22%, P = 0.315).
CONCLUSION: In TAVI cases with unfavorable contralateral femoral anatomy, radial CT for vascular access management is a reasonable alternative to the femoral CT.
BACKGROUND: Femoral crossover for controlled angiography and balloon inflation of the therapeutic access site to facilitate safe vascular closure is beneficial but technically challenging in patients with complex femoral anatomy. An alternative approach should be available.
METHODS: Between June 2011 and March 2012, 41 transfemoral TAVI patients receiving the femoral CT were compared to 46 transfemoral TAVI patients receiving the radial CT. Outcomes were 30-day valve academic research consortium (VARC) endpoints.
RESULTS: Patients undergoing the radial CT received higher median contrast volumes (150 interquartile range [IQR]: 105-180 vs. 111 IQR: 90-139 ml; P = 0.025) but procedural radiation dose and fluoroscopy times were comparable. Thirty day all cause and cardiovascular death were similar between radial and femoral CT groups (respectively 2.4% vs. 7.9%, P = 0.258 and 0% vs. 7.9%, P = 0.063). There were no differences in major vascular complications (4.3% vs. 7.3%, P = 0.553), life threatening or major bleeding events (respectively 9.1% vs. 19.5%, P = 0.168 and 13.6% vs. 22%, P = 0.315).
CONCLUSION: In TAVI cases with unfavorable contralateral femoral anatomy, radial CT for vascular access management is a reasonable alternative to the femoral CT.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app