JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Real-time left ventricular pressure-volume loops during percutaneous mitral valve repair with the MitraClip system.

Circulation 2013 March 6
BACKGROUND: Percutaneous mitral valve repair with the MitraClip device has emerged as an alternative to surgery for treating severe mitral regurgitation. However, its effects on left ventricular loading conditions and contractility have not been investigated yet.

METHODS AND RESULTS: Pressure-volume loops were recorded throughout the MitraClip procedure using conductance catheter in 33 patients (mean age, 78±10 years) with functional (45%), degenerative (48%), or mixed (6%) mitral regurgitation. Percutaneous mitral valve repair increased end-systolic wall stress (WSES; from [median] 184 mm Hg [interquartile range (IQR), 140-200 mm Hg] to 209 mm Hg [IQR, 176-232 mm Hg]; P=0.001) and decreased end-diastolic WS (WSED; from 48 mm Hg [IQR, 28-58 mm Hg] to 34 mm Hg [IQR, 21-46 mm Hg]; P=0.005), whereas the end-systolic pressure-volume relationship was not significantly affected. Conversely, cardiac index increased (from 2.6 L·min(-1)·m(-2) [IQR, 2.2-3.0 L·min(-1)·m(-2)] to 3.2 L·min(-1)·m(-2) [IQR, 2.6-3.8 L·min(-1)·m(-2)]; P<0.001) and mean pulmonary capillary wedge pressure decreased (from 15 mm Hg [IQR, 12-20 mm Hg] to 12 mm Hg [IQR, 10-13 mm Hg]; P<0.001). Although changes in WSES were not correlated with changes in cardiac index, changes in WSED correlated significantly with changes in mean pulmonary capillary wedge pressure (r=0.63, P<0.001). Total mechanical energy assessed by the pressure-volume area remained unchanged, resulting in a more favorable index of forward output (cardiac index) to mechanical energy (pressure-volume area) after mitral valve repair. On follow-up (153±94 days), New York Heart Association functional class was reduced from 2.9±0.6 to 1.9±0.5 (P<0.001) at 3 months, and echocardiographic follow-up documented a stepwise reduction in end-diastolic volume (from 147 mL [IQR, 95-191 mL] to 127 mL [IQR, 82-202 mL]; P=0.036).

CONCLUSIONS: Percutaneous mitral valve repair improves hemodynamic profiles and induces reverse left ventricular remodeling by reducing left ventricular preload while preserving contractility. In nonsurgical candidates with compromised left ventricular function, MitraClip therapy could be considered an alternative to surgical mitral valve repair.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app