We have located links that may give you full text access.
Comparative Study
Journal Article
Comparison of infectious complications with synthetic mesh in ventral hernia repair.
American Journal of Surgery 2013 Februrary
BACKGROUND: Infection can be a devastating complication associated with prosthetic incisional hernia repair. It is unclear whether the type of mesh used affects the risk of infection.
METHODS: A retrospective review was performed of all patients who underwent elective incisional hernia repair with permanent prosthetic mesh between January 1, 2000, and August 1, 2007.
RESULTS: A total of 176 patients underwent elective incisional hernia repair with mesh. The overall infection rate with the use of goretex (Flagstaff, AZ, USA) was 12 of 86 (14%) and 2 of 90 (2.2%) in cases in which nongoretex material was used (P = .016). In the goretex group, infection rates were significantly higher in open versus laparoscopic cases (26.5% vs 5.8%, P = .030). Methicillin-resistant Staphylococcus aureus was the most common organism recovered.
CONCLUSIONS: The risk of mesh infection with the use of goretex was found to be higher than with the use of nongoretex mesh. Laparoscopic placement of goretex reduces this risk of infection. No significant differences in recurrence rates were found.
METHODS: A retrospective review was performed of all patients who underwent elective incisional hernia repair with permanent prosthetic mesh between January 1, 2000, and August 1, 2007.
RESULTS: A total of 176 patients underwent elective incisional hernia repair with mesh. The overall infection rate with the use of goretex (Flagstaff, AZ, USA) was 12 of 86 (14%) and 2 of 90 (2.2%) in cases in which nongoretex material was used (P = .016). In the goretex group, infection rates were significantly higher in open versus laparoscopic cases (26.5% vs 5.8%, P = .030). Methicillin-resistant Staphylococcus aureus was the most common organism recovered.
CONCLUSIONS: The risk of mesh infection with the use of goretex was found to be higher than with the use of nongoretex mesh. Laparoscopic placement of goretex reduces this risk of infection. No significant differences in recurrence rates were found.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app