We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Comparison of single domain antibody immobilization strategies evaluated by surface plasmon resonance.
Journal of Immunological Methods 2013 Februrary 29
The use of single domain antibodies (sdAbs) in place of conventional antibodies for both therapeutic and diagnostic applications continues to grow. SdAbs offer a number of advantages when compared to conventional antibodies such as their small size and low structural complexity which allows them to readily be produced as fusions in a variety formats. In this work we compared the utility of various C-terminal fusions and immobilization strategies for two sdAbs; one which recognizes ricin and the other EA1, an S-layer protein, of Bacillus anthracis. Comparisons were made between direct covalent attachment and affinity immobilization using a biotin-streptavidin interaction for the standard sdAb monomers, randomly and site-specifically biotinylated monomers, and fusion constructs of alkaline phosphatase dimers and streptavidin core tetramers. The sdAb binding and regeneration was evaluated by surface plasmon resonance in a multiplexed format. The construct that provided the highest density of active molecules by at least a factor of two was the sdAb-streptavidin core tetramer, followed by the sdAb-alkaline phosphatase and then the site-specifically biotinylated monomer. The poorest performing immobilization methods were the two most common, direct covalent attachment and the randomly biotinylated sdAb attached via NeutrAvidin. These improvements directly correlated to antigen capture in SPR assays. Similarly, the oriented immobilization method also translated to improvements in limit of detection assays using a bead-based system. The sdAb-streptavidin core provided more than a 100-fold improvement in the limit of detection of EA1, from ~200 ng/mL to to 1.6 ng/mL, while improvement for ricin detection was less but still a significant 5-fold decrease, going from 1.6 ng/mL down to 0.32 ng/mL. This demonstrated improvement in limits of detection is an advantage that should be transferable to most assay formats.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app