Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Automated quantitative 3-dimensional modeling of the aortic valve and root by 3-dimensional transesophageal echocardiography in normals, aortic regurgitation, and aortic stenosis: comparison to computed tomography in normals and clinical implications.

BACKGROUND: We tested the ability of a novel automated 3-dimensional (3D) algorithm to model and quantify the aortic root from 3D transesophageal echocardiography (TEE) and computed tomographic (CT) data.

METHODS AND RESULTS: We compared the quantitative parameters obtained by automated modeling from 3D TEE (n=20) and CT data (n=20) to those made by 2D TEE and targeted 2D from 3D TEE and CT in patients without valve disease (normals). We also compared the automated 3D TEE measurements in severe aortic stenosis (n=14), dilated root without aortic regurgitation (n=15), and dilated root with aortic regurgitation (n=20). The automated 3D TEE sagittal annular diameter was significantly greater than the 2D TEE measurements (P=0.004). This was also true for the 3D TEE and CT coronal annular diameters (P<0.01). The average 3D TEE and CT annular diameter was greater than both their respective 2D and 3D sagittal diameters (P<0.001). There was no significant difference in 2D and 3D measurements of the sinotubular junction and sinus of valsalva diameters (P>0.05) in normals, but these were significantly different (P<0.05) in abnormals. The 3 automated intercommissural distance and leaflet length and height did not show significant differences in the normals (P>0.05), but all 3 were significantly different compared with the abnormal group (P<0.05). The automated 3D annulus commissure coronary ostia distances in normals showed significant difference between 3D TEE and CT (P<0.05); also, these parameters by automated 3D TEE were significantly different in abnormal (P<0.05). Finally, the automated 3D measurements showed excellent reproducibility for all parameters.

CONCLUSIONS: Automated quantitative 3D modeling of the aortic root from 3D TEE or CT data is technically feasible and provides unique data that may aid surgical and transcatheter interventions.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app