COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Femtosecond laser-assisted cataract surgery compared with conventional cataract surgery.

BACKGROUND: To investigate the safety and efficacy of the Catalys (Optimedica, Santa Clara, CA, USA) femtosecond laser-assisted cataract surgery system compared with conventional phacoemulsification cataract extraction.

DESIGN: Prospective, consecutive, parallel cohort study.

PARTICIPANTS: The first 200 eyes undergoing conventional cataract surgery to the first 200 eyes undergoing femtosecond laser-assisted cataract surgery between April and July 2012.

METHODS: Femtosecond laser-assisted cataract surgery involved anterior capsulotomy and lens fragmentation based on optical coherence tomography-guided treatment mapping. Conventional cataract surgery involved manual continuous curvilinear capsulorhexis. Both procedures were completed by standard phacoemulsification and insertion of an intraocular lens.

MAIN OUTCOME MEASURES: Effective phacoemulsification time and intraoperative complication rates.

RESULTS: Patient demographics were similar between both groups. There was no statistically significant difference in intraoperative complications between femtosecond laser-assisted cataract surgery and conventional surgery. There was one posterior capsule rupture in both groups (0.5%; not significant). One hundred per cent of cases treated with the femtosecond laser had a complete capsulotomy. Vacuum time decreased with experience. Effective phacoemulsification time was reduced by 70% in the femtosecond group (P < 0.0001). Twenty-six cases in the femtosecond group versus one case in the conventional group had 0 effective phacoemulsification time (P < 0.0001).

CONCLUSION: Femtosecond laser-assisted cataract surgery appears to be as safe as conventional cataract surgery in the short term and results in significantly lower effective phacoemulsification time. Although it may allow for greater efficiency and decreased postoperative complications, further research is needed into long-term safety aspects such as corneal endothelial cell loss.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app